− | == Introduction == | + | == Introduction == |
| | | |
− | <u>disambiguation</u>:<br> | + | <u>disambiguation</u>:<br> |
| | | |
− | grid connection<br> | + | grid connection<br> |
| | | |
− | island / isolated grids<br> | + | island / isolated grids<br> |
| | | |
| battery storage / charging stations | | battery storage / charging stations |
| | | |
| + | == '''Off-Grid Battery-Based Microhydro-Electric Systems''' == |
| | | |
| + | <span>Most small off-grid hydro systems are battery-based. Battery |
| + | systems have great flexibility and can be |
| + | combined with other energy sources, such as wind generators and |
| + | solar-electric |
| + | arrays, if the stream is seasonal. Because stream flow is usually |
| + | consistent, |
| + | battery charging is as well, and it´s often possible to use a relatively |
| + | </span> |
| + | |
| + | small |
| + | |
| + | battery bank. Instantaneous demand (watts) will be limited not by the water potential or turbine, but by the size of the inverter. |
| + | |
| + | <span>The following illustration includes the primary |
| + | components of any off-grid battery-based microhydro-electric system..</span> |
| + | |
| + | picture... <br> |
| + | |
| + | == '''Off-Grid Batteryless Microhydro-Electric Systems''' == |
| + | |
| + | <span>If the stream has enough potential, one may decide to |
| + | go with an AC-direct system. This consists of a turbine generator that |
| + | produces |
| + | AC output at 120 or 240 volts, which can be sent directly to standard |
| + | household |
| + | loads. The system is controlled by diverting energy in excess of load |
| + | requirements |
| + | to dump loads, such as water- or air-heating elements. This technique |
| + | keeps the |
| + | total load on the generator constant. A limitation of these systems is |
| + | that the |
| + | peak or surge loads cannot exceed the output of the generator, which is |
| + | determined by the stream´s available head and flow. This type of system |
| + | needs |
| + | to be large to meet peak electrical loads, so it can often generate |
| + | enough |
| + | energy for all household needs, including water and space heating.</span> |
| + | |
| + | <span>The following illustration includes the primary components |
| + | of any off-grid batteryless microhydro-electric system. </span> |
| + | |
| + | <!--{12766841534923}-->picture .... |
| + | |
| + | <br> |
| + | |
| + | |
| + | |
| + | == '''Grid-Tied Batteryless Microhydro-Electric Systems''' == |
| + | |
| + | <span>Systems of this type use a turbine and controls to |
| + | produce electricity that can be fed directly into utility lines. These |
| + | can use |
| + | either AC or DC generators. AC systems will use AC generators to sync |
| + | directly |
| + | with the grid. An approved interface device is needed to prevent the |
| + | system |
| + | from energizing the grid when the grid is out of action and under |
| + | repair. DC |
| + | systems will use a specific inverter to convert the output of a DC hydro |
| + | turbine to grid-synchronous AC. The biggest drawback of batteryless |
| + | systems is |
| + | that when the utility is down, your electricity will be out too. When |
| + | the grid |
| + | fails, these systems are designed to automatically shut down.</span> |
| + | |
| + | <span>The following illustration includes the primary |
| + | components of any grid-tied batteryless microhydro-electric system. </span> |
| + | |
| + | <!--{12766841534924}--> |
| + | |
| + | [[|]]'''<span>Microhydro-Electric</span>''' System Components |
| + | |
| + | '''Controls'''<span> |
| + | </span> |
| + | |
| + | AKA: Charge controller, controller, regulator |
| + | |
| + | <!--{12766841534925}-->[[Image:|Controller]] |
| + | |
| + | |
| + | |
| + | <span>The function of a |
| + | charge controller in a hydro system is equivalent to turning on a load |
| + | to |
| + | absorb excess energy. Battery-based microhydro systems require charge |
| + | controllers to prevent overcharging the batteries. Controllers generally |
| + | </span> |
| + | |
| + | send |
| + | |
| + | excess energy to a secondary (dump) load, such as an air or water heater. Unlike a solar-electric controller, a microhydro system controller does not disconnect the turbine from the batteries. This could create voltages that are higher than some components can withstand, or cause the turbine to overspeed, which could result in dangerous and damaging overvoltages. |
| + | |
| + | <span>Off-grid, batteryless |
| + | AC-direct microhydro systems need controls too. A load-control governor |
| + | monitors the voltage or frequency of the system, and keeps the generator |
| + | correctly loaded, turning dump-load capacity on and off as the load |
| + | pattern |
| + | changes, or mechanically deflects water away from the runner. Grid-tied |
| + | batteryless AC and DC systems also need controls to protect the system |
| + | if the |
| + | utility grid fails.</span> |
| + | |
| + | == '''Dump Load''' == |
| + | |
| + | AKA: diversion load, shunt load |
| + | |
| + | <!--{12766841534926}-->[[Image:|Dump Load 1]]<!--{12766841534927}-->[[Image:|Dump Load 2]] |
| + | |
| + | <span>A dump |
| + | load is an electrical resistance heater that must be sized to handle the |
| + | </span> |
| + | |
| + | full |
| + | |
| + | generating capacity of the microhydro turbine. Dump loads can be air or water heaters, and are activated by the charge controller whenever the batteries or the grid cannot accept the energy being produced, to prevent damage to the system. Excess energy is "shunted" to the dump load when necessary. |
| + | |
| + | |
| + | |
| + | |
| + | |
| + | == '''<span>Battery</span> Bank''' == |
| + | |
| + | AKA: storage battery |
| + | |
| + | <!--{12766841534928}-->[[Image:|Battery Bank]] |
| + | |
| + | <span>By using |
| + | reversible chemical reactions, a battery bank provides a way to store |
| + | surplus |
| + | energy when more is being produced than consumed. When demand increases |
| + | beyond |
| + | what is generated, the batteries can be called on to release energy to |
| + | keep |
| + | your household loads operating.</span> |
| + | |
| + | <span>A |
| + | microhydro system is typically the most gentle of the RE systems on the |
| + | batteries, since they do not often remain in a discharged state. The |
| + | bank can |
| + | also be smaller than for a wind or PV system. One or two days of storage |
| + | </span> |
| + | |
| + | is |
| + | |
| + | usually sufficient. Deep-cycle lead-acid batteries are typically used in |
| + | |
| + | these |
| + | |
| + | systems. They are cost effective and do not usually account for a large percentage of the system cost. |
| + | |
| + | |
| + | |
| + | == '''Metering''' == |
| + | |
| + | <span>AKA: |
| + | battery monitor, amp-hour meter, watt-hour meter</span> |
| + | |
| + | <!--{12766841534929}-->[[Image:|Metering]] |
| + | |
| + | <span>System |
| + | meters measure and display several different aspects of your |
| + | microhydro-electric system´s performance and status—tracking how full |
| + | your |
| + | battery bank is, how much electricity your turbine is producing or has |
| + | produced, and how much electricity is being used. Operating your system |
| + | without |
| + | metering is like running your car without any gauges—although possible |
| + | to do, |
| + | it´s always better to know how well the car is operating and how much |
| + | fuel is |
| + | in the tank.</span> |
| + | |
| + | |
| + | |
| + | [[|]]'''<span>Main DC</span>''' Disconnect |
| + | |
| + | == '''AKA: Battery/Inverter disconnect''' == |
| + | |
| + | <!--{127668415349210}-->[[Image:|Main DC Disconnect]] |
| + | |
| + | <span>In |
| + | battery-based systems, a disconnect between the batteries and inverter |
| + | is |
| + | required. This disconnect is typically a large, DC-rated breaker mounted |
| + | </span> |
| + | |
| + | in a |
| + | |
| + | sheet-metal enclosure. It allows the inverter to be disconnected from the batteries for service, and protects the inverter-to-battery wiring against electrical faults. |
| + | |
| + | |
| + | |
| + | |
| + | |
| + | == '''Inverter''' == |
| + | |
| + | <span>AKA: DC-to-AC |
| + | converter </span> |
| + | |
| + | <!--{127668415349211}-->[[Image:|Battery-Based Inverter]]<span>Inverters |
| + | transform |
| + | </span> |
| + | |
| + | the DC electricity stored in your battery bank into AC electricity |
| + | |
| + | for powering household appliances. Grid-tied inverters synchronize the system´s output with the utility´s AC electricity, allowing the system to feed hydro-electricity to the utility grid. Battery-based inverters for off-grid or grid-tied systems often include a battery charger, which is capable of charging a battery bank from either the grid or a backup generator if your creek isn´t flowing or your system is down for maintenance. |
| + | |
| + | <span>In rare |
| + | cases, an inverter and battery bank are used with larger, off-grid |
| + | AC-direct |
| + | systems to increase power availability. The inverter uses the AC to |
| + | charge the |
| + | batteries, and synchronizes with the hydro-electric AC supply to |
| + | supplement it |
| + | when demand is greater than the output of the hydro generator.</span> |
| + | |
| + | [[|]]'''<span>AC</span>''' Breaker Panel |
| + | |
| + | AKA: mains panel, breaker box, service entrance |
| + | |
| + | <!--{127668415349212}-->[[Image:|AC Breaker Panel]] |
| + | |
| + | <span>The AC |
| + | breaker panel, or mains panel, is the point at which all of a home´s |
| + | electrical |
| + | wiring meets with the provider of the electricity, whether that´s the |
| + | grid or a |
| + | microhydro-electric system. This wall-mounted panel or box is usually |
| + | installed |
| + | in a utility room, basement, garage, or on the exterior of a building. |
| + | It |
| + | contains a number of labeled circuit breakers that route electricity to |
| + | the various |
| + | rooms throughout a house. These breakers allow electricity to be |
| + | disconnected |
| + | for servicing, and also protect the building´s wiring against electrical |
| + | </span> |
| + | |
| + | fires. |
| + | |
| + | <span>Just like |
| + | the electrical circuits in your home or office, a grid-tied inverter´s |
| + | electrical output needs to be routed through an AC circuit breaker. This |
| + | breaker is usually mounted inside the building´s mains panel. It enables |
| + | </span> |
| + | |
| + | the |
| + | |
| + | inverter to be disconnected from either the grid or from electrical loads if servicing is necessary. The breaker also safeguards the circuit´s electrical wiring. |
| + | |
| + | ''' ''' |
| + | |
| + | [[|]]'''Kilowatt-Hour Meter''' |
| + | |
| + | <span>AKA: KWH |
| + | meter, utility meter</span> |
| + | |
| + | <!--{127668415349213}-->[[Image:|Kilowatt-Hour Meter]] |
| + | |
| + | <span>Most |
| + | homes with grid-tied microhydro-electric systems will have AC |
| + | electricity both |
| + | coming from and going to the utility grid. A multichannel KWH meter |
| + | keeps track |
| + | of how much grid electricity you´re using and how much your RE system is |
| + | producing. The utility company often provides intertie-capable meters at |
| + | </span> |
| + | |
| + | no |
| + | |
| + | cost. |
| + | |
| + | ''' ''' |
| + | |
| + | ''' ''' |
| + | |
| + | ''' ''' |
| + | |
| + | ''' ''' |
| + | |
| + | ''' ''' |
| + | |
| + | ''' ''' |
| + | |
| + | == ''''Turbines'types''' == |
| + | |
| + | <span><!--{127668415349214}-->[[Image:]]</span> |
| + | |
| + | <span>A turbine converts the energy in |
| + | falling water into shaft power. There are various types of turbine which |
| + | </span> |
| + | |
| + | can be |
| + | |
| + | categorised in one of several ways. The choice of turbine will depend mainly on the pressure head available and the design flow for the proposed hydropower installation. As shown in table 2 below, turbines are broadly divided into three groups; high, medium and low head, and into two categories: impulse and reaction. |
| + | |
| + | {| cellpadding="0" border="1" |
| + | |- |
| + | | valign="top" rowspan="2" | <br> |
| + | '''<span>Turbine</span> ''' |
| + | |
| + | '''Runner''' |
| + | |
| + | | valign="top" align="center" colspan="3" | |
| + | '''<span>Head</span> ''' |
| + | |
| + | '''pressure''' |
| + | |
| + | |- |
| + | | valign="top" align="center" | |
| + | '''High''' |
| + | |
| + | | valign="top" align="center" | |
| + | '''Medium''' |
| + | |
| + | | valign="top" align="center" | |
| + | '''Low'''<br> |
| + | |
| + | |- |
| + | | valign="top" | |
| + | Impulse |
| + | |
| + | | valign="top" | |
| + | <span>Pelton |
| + | </span> |
| + | |
| + | Turgo |
| + | |
| + | Multi-jet Pelton <br> |
| + | |
| + | | valign="top" | |
| + | <span>Crossflow |
| + | </span> |
| + | |
| + | Turgo |
| + | |
| + | Multi-jet Pelton <br> |
| + | |
| + | | valign="top" | |
| + | Crossflow |
| + | |
| + | |- |
| + | | valign="top" | |
| + | Reaction |
| + | |
| + | | valign="top" | |
| + | <span>Francis |
| + | </span> |
| + | |
| + | Pump-as-turbine (PAT) <br> |
| + | |
| + | | valign="top" | |
| + | <span>Propeller |
| + | </span> |
| + | |
| + | Kaplan <br> |
| + | |
| + | | valign="top" | |
| + | |
| + | |
| + | |} |
| + | |
| + | ''' ''' |
| + | |
| + | <span>The difference between impulse and |
| + | reaction can be explained simply by stating that the ''impulse'' |
| + | turbines |
| + | convert the kinetic energy of a jet of water in air into movement by |
| + | striking |
| + | turbine buckets or blades - there is no pressure reduction as the water |
| + | pressure is atmospheric on both sides of the impeller. The blades of a ''reaction'' |
| + | turbine, on the other hand, are totally immersed in the flow of water, |
| + | and the |
| + | angular as well as linear momentum of the water is converted into shaft |
| + | power - |
| + | the pressure of water leaving the runner is reduced to atmospheric or |
| + | lower. </span> |
| + | |
| + | == '''Load factor''' == |
| + | |
| + | <span>The load factor is the amount of |
| + | power used divided by the amount of power that is available if the |
| + | turbine were |
| + | to be used continuously. Unlike technologies relying on costly fuel |
| + | sources, |
| + | the 'fuel' for hydropower generation is free and therefore the plant |
| + | becomes |
| + | more cost effective if run for a high percentage of the time. If the |
| + | turbine is |
| + | only used for domestic lighting in the evenings then the plant factor |
| + | will be |
| + | very low. If the turbine provides power for rural industry during the |
| + | day, |
| + | meets domestic demand during the evening, and maybe pumps water for |
| + | irrigation |
| + | in the evening, then the plant factor will be high. </span> |
| + | |
| + | <span>It is very important to ensure a |
| + | high plant factor if the scheme is to be cost effective and this should |
| + | be |
| + | taken into account during the planning stage. Many schemes use a 'dump' |
| + | load |
| + | (in conjunction with an electronic load controller - see below), which |
| + | is |
| + | effectively a low priority energy demand that can accept surplus energy |
| + | when an |
| + | excess is produced e.g. water heating, storage heaters or storage |
| + | cookers. </span> |
| + | |
| + | == '''Load control governors''' == |
| + | |
| + | <span>Water turbines, like petrol or |
| + | diesel engines, will vary in speed as load is applied or relieved. |
| + | Although not |
| + | such a great problem with machinery which uses direct shaft power, this |
| + | speed |
| + | variation will seriously affect both frequency and voltage output from a |
| + | generator. Traditionally, complex hydraulic or mechanical speed |
| + | governors |
| + | altered flow as the load varied, but more recently an electronic load |
| + | controller (ELC) has been developed which has increased the simplicity |
| + | and |
| + | reliability of modern micro-hydro sets. The ELC prevents speed |
| + | variations by |
| + | continuously adding or subtracting an artificial load, so that in |
| + | effect, the |
| + | turbine is working permanently under full load. A further benefit is |
| + | that the |
| + | ELC has no moving parts, is very reliable and virtually maintenance |
| + | free. The |
| + | advent of electronic load control has allowed the introduction of simple |
| + | </span> |
| + | |
| + | and |
| + | |
| + | efficient, multi-jet turbines, no longer burdened by expensive hydraulic governors. |
| + | |
| + | <br> |
| | | |
| == Controller: <br> == | | == Controller: <br> == |
Line 17: |
Line 456: |
| <span id="1274973221030S" style="display: none;"> </span> | | <span id="1274973221030S" style="display: none;"> </span> |
| | | |
− | <!--{12766848790533}--><!--{12766848790534}--><!--{12766848790535}--><span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">Function </span><span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">[[Image:Mhp-scheme.jpg|right|560x386px|Elements of a Micro Hydro Power Scheme]]principles</span><br> | + | <!--{12766848790533}--><!--{12766848790534}--><!--{12766848790535}--><span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">Function </span><span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">[[Image:Mhp-scheme.jpg|right|560x386px|Elements of a Micro Hydro Power Scheme]]principles</span><br> |
| | | |
| Load- or Flow- controller ensure that the power output does not exceed the power demand (e.g. 230V, 50 Hz). <br> If flow of water in a MHP-station is constant the energy output of a turbine/generator is constant as well. Power demand is usually fluctuating over the time (e.g. day/night). If supply is higher than demand, excess energy must be diverted, dumped. alternatively the water flow can be reduced which results in less power output. <br> In case of more power demand than supply the controller cuts of the of demand line. <br> Load controller are placed between generator output and the consumer line.<!--{12766848790536}--> <span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;"> | | Load- or Flow- controller ensure that the power output does not exceed the power demand (e.g. 230V, 50 Hz). <br> If flow of water in a MHP-station is constant the energy output of a turbine/generator is constant as well. Power demand is usually fluctuating over the time (e.g. day/night). If supply is higher than demand, excess energy must be diverted, dumped. alternatively the water flow can be reduced which results in less power output. <br> In case of more power demand than supply the controller cuts of the of demand line. <br> Load controller are placed between generator output and the consumer line.<!--{12766848790536}--> <span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;"> |
Line 52: |
Line 491: |
| Nowadays flow control is done mostly via electronics (which steer a valve) | | Nowadays flow control is done mostly via electronics (which steer a valve) |
| | | |
− | [[Image:Flow-control.jpg|left|650x264px|principle flow control]] | + | [[Image:Flow-control.jpg|left|650x264px|principle flow control]] |
| + | |
| + | [[Category:Hydro]] |
Revision as of 11:45, 16 June 2010
Introduction
disambiguation:
grid connection
island / isolated grids
battery storage / charging stations
Off-Grid Battery-Based Microhydro-Electric Systems
Most small off-grid hydro systems are battery-based. Battery
systems have great flexibility and can be
combined with other energy sources, such as wind generators and
solar-electric
arrays, if the stream is seasonal. Because stream flow is usually
consistent,
battery charging is as well, and it´s often possible to use a relatively
small
battery bank. Instantaneous demand (watts) will be limited not by the water potential or turbine, but by the size of the inverter.
The following illustration includes the primary
components of any off-grid battery-based microhydro-electric system..
picture...
Off-Grid Batteryless Microhydro-Electric Systems
If the stream has enough potential, one may decide to
go with an AC-direct system. This consists of a turbine generator that
produces
AC output at 120 or 240 volts, which can be sent directly to standard
household
loads. The system is controlled by diverting energy in excess of load
requirements
to dump loads, such as water- or air-heating elements. This technique
keeps the
total load on the generator constant. A limitation of these systems is
that the
peak or surge loads cannot exceed the output of the generator, which is
determined by the stream´s available head and flow. This type of system
needs
to be large to meet peak electrical loads, so it can often generate
enough
energy for all household needs, including water and space heating.
The following illustration includes the primary components
of any off-grid batteryless microhydro-electric system.
picture ....
Grid-Tied Batteryless Microhydro-Electric Systems
Systems of this type use a turbine and controls to
produce electricity that can be fed directly into utility lines. These
can use
either AC or DC generators. AC systems will use AC generators to sync
directly
with the grid. An approved interface device is needed to prevent the
system
from energizing the grid when the grid is out of action and under
repair. DC
systems will use a specific inverter to convert the output of a DC hydro
turbine to grid-synchronous AC. The biggest drawback of batteryless
systems is
that when the utility is down, your electricity will be out too. When
the grid
fails, these systems are designed to automatically shut down.
The following illustration includes the primary
components of any grid-tied batteryless microhydro-electric system.
[[|]]Microhydro-Electric System Components
Controls
AKA: Charge controller, controller, regulator
[[Image:|Controller]]
The function of a
charge controller in a hydro system is equivalent to turning on a load
to
absorb excess energy. Battery-based microhydro systems require charge
controllers to prevent overcharging the batteries. Controllers generally
send
excess energy to a secondary (dump) load, such as an air or water heater. Unlike a solar-electric controller, a microhydro system controller does not disconnect the turbine from the batteries. This could create voltages that are higher than some components can withstand, or cause the turbine to overspeed, which could result in dangerous and damaging overvoltages.
Off-grid, batteryless
AC-direct microhydro systems need controls too. A load-control governor
monitors the voltage or frequency of the system, and keeps the generator
correctly loaded, turning dump-load capacity on and off as the load
pattern
changes, or mechanically deflects water away from the runner. Grid-tied
batteryless AC and DC systems also need controls to protect the system
if the
utility grid fails.
Dump Load
AKA: diversion load, shunt load
[[Image:|Dump Load 1]][[Image:|Dump Load 2]]
A dump
load is an electrical resistance heater that must be sized to handle the
full
generating capacity of the microhydro turbine. Dump loads can be air or water heaters, and are activated by the charge controller whenever the batteries or the grid cannot accept the energy being produced, to prevent damage to the system. Excess energy is "shunted" to the dump load when necessary.
Battery Bank
AKA: storage battery
[[Image:|Battery Bank]]
By using
reversible chemical reactions, a battery bank provides a way to store
surplus
energy when more is being produced than consumed. When demand increases
beyond
what is generated, the batteries can be called on to release energy to
keep
your household loads operating.
A
microhydro system is typically the most gentle of the RE systems on the
batteries, since they do not often remain in a discharged state. The
bank can
also be smaller than for a wind or PV system. One or two days of storage
is
usually sufficient. Deep-cycle lead-acid batteries are typically used in
these
systems. They are cost effective and do not usually account for a large percentage of the system cost.
Metering
AKA:
battery monitor, amp-hour meter, watt-hour meter
[[Image:|Metering]]
System
meters measure and display several different aspects of your
microhydro-electric system´s performance and status—tracking how full
your
battery bank is, how much electricity your turbine is producing or has
produced, and how much electricity is being used. Operating your system
without
metering is like running your car without any gauges—although possible
to do,
it´s always better to know how well the car is operating and how much
fuel is
in the tank.
[[|]]Main DC Disconnect
AKA: Battery/Inverter disconnect
[[Image:|Main DC Disconnect]]
In
battery-based systems, a disconnect between the batteries and inverter
is
required. This disconnect is typically a large, DC-rated breaker mounted
in a
sheet-metal enclosure. It allows the inverter to be disconnected from the batteries for service, and protects the inverter-to-battery wiring against electrical faults.
Inverter
AKA: DC-to-AC
converter
[[Image:|Battery-Based Inverter]]Inverters
transform
the DC electricity stored in your battery bank into AC electricity
for powering household appliances. Grid-tied inverters synchronize the system´s output with the utility´s AC electricity, allowing the system to feed hydro-electricity to the utility grid. Battery-based inverters for off-grid or grid-tied systems often include a battery charger, which is capable of charging a battery bank from either the grid or a backup generator if your creek isn´t flowing or your system is down for maintenance.
In rare
cases, an inverter and battery bank are used with larger, off-grid
AC-direct
systems to increase power availability. The inverter uses the AC to
charge the
batteries, and synchronizes with the hydro-electric AC supply to
supplement it
when demand is greater than the output of the hydro generator.
[[|]]AC Breaker Panel
AKA: mains panel, breaker box, service entrance
[[Image:|AC Breaker Panel]]
The AC
breaker panel, or mains panel, is the point at which all of a home´s
electrical
wiring meets with the provider of the electricity, whether that´s the
grid or a
microhydro-electric system. This wall-mounted panel or box is usually
installed
in a utility room, basement, garage, or on the exterior of a building.
It
contains a number of labeled circuit breakers that route electricity to
the various
rooms throughout a house. These breakers allow electricity to be
disconnected
for servicing, and also protect the building´s wiring against electrical
fires.
Just like
the electrical circuits in your home or office, a grid-tied inverter´s
electrical output needs to be routed through an AC circuit breaker. This
breaker is usually mounted inside the building´s mains panel. It enables
the
inverter to be disconnected from either the grid or from electrical loads if servicing is necessary. The breaker also safeguards the circuit´s electrical wiring.
[[|]]Kilowatt-Hour Meter
AKA: KWH
meter, utility meter
[[Image:|Kilowatt-Hour Meter]]
Most
homes with grid-tied microhydro-electric systems will have AC
electricity both
coming from and going to the utility grid. A multichannel KWH meter
keeps track
of how much grid electricity you´re using and how much your RE system is
producing. The utility company often provides intertie-capable meters at
no
cost.
'Turbines'types
[[Image:]]
A turbine converts the energy in
falling water into shaft power. There are various types of turbine which
can be
categorised in one of several ways. The choice of turbine will depend mainly on the pressure head available and the design flow for the proposed hydropower installation. As shown in table 2 below, turbines are broadly divided into three groups; high, medium and low head, and into two categories: impulse and reaction.
Turbine
Runner
|
Head
pressure
|
High
|
Medium
|
Low
|
Impulse
|
Pelton
Turgo
Multi-jet Pelton
|
Crossflow
Turgo
Multi-jet Pelton
|
Crossflow
|
Reaction
|
Francis
Pump-as-turbine (PAT)
|
Propeller
Kaplan
|
|
The difference between impulse and
reaction can be explained simply by stating that the impulse
turbines
convert the kinetic energy of a jet of water in air into movement by
striking
turbine buckets or blades - there is no pressure reduction as the water
pressure is atmospheric on both sides of the impeller. The blades of a reaction
turbine, on the other hand, are totally immersed in the flow of water,
and the
angular as well as linear momentum of the water is converted into shaft
power -
the pressure of water leaving the runner is reduced to atmospheric or
lower.
Load factor
The load factor is the amount of
power used divided by the amount of power that is available if the
turbine were
to be used continuously. Unlike technologies relying on costly fuel
sources,
the 'fuel' for hydropower generation is free and therefore the plant
becomes
more cost effective if run for a high percentage of the time. If the
turbine is
only used for domestic lighting in the evenings then the plant factor
will be
very low. If the turbine provides power for rural industry during the
day,
meets domestic demand during the evening, and maybe pumps water for
irrigation
in the evening, then the plant factor will be high.
It is very important to ensure a
high plant factor if the scheme is to be cost effective and this should
be
taken into account during the planning stage. Many schemes use a 'dump'
load
(in conjunction with an electronic load controller - see below), which
is
effectively a low priority energy demand that can accept surplus energy
when an
excess is produced e.g. water heating, storage heaters or storage
cookers.
Load control governors
Water turbines, like petrol or
diesel engines, will vary in speed as load is applied or relieved.
Although not
such a great problem with machinery which uses direct shaft power, this
speed
variation will seriously affect both frequency and voltage output from a
generator. Traditionally, complex hydraulic or mechanical speed
governors
altered flow as the load varied, but more recently an electronic load
controller (ELC) has been developed which has increased the simplicity
and
reliability of modern micro-hydro sets. The ELC prevents speed
variations by
continuously adding or subtracting an artificial load, so that in
effect, the
turbine is working permanently under full load. A further benefit is
that the
ELC has no moving parts, is very reliable and virtually maintenance
free. The
advent of electronic load control has allowed the introduction of simple
and
efficient, multi-jet turbines, no longer burdened by expensive hydraulic governors.
Controller:
Function principles
Load- or Flow- controller ensure that the power output does not exceed the power demand (e.g. 230V, 50 Hz).
If flow of water in a MHP-station is constant the energy output of a turbine/generator is constant as well. Power demand is usually fluctuating over the time (e.g. day/night). If supply is higher than demand, excess energy must be diverted, dumped. alternatively the water flow can be reduced which results in less power output.
In case of more power demand than supply the controller cuts of the of demand line.
Load controller are placed between generator output and the consumer line.
Controller Types
Load controller:
Electronic circuit, which keeps output power constant in Frequency- and Voltage- parameters.
Fluctuating energy demand requires a mechanism which either regulates the water input into the turbine (= flow control) or by diverting excess energy from the consumer connection (= ballast load).
Ballast load
usually electrical heaters in water or air. If energy demand is temporarily low the excess energy is converted into heat.
Flow control
regulates the amount of water into the turbine in order to match power output and power demand.
Nowadays flow control is done mostly via electronics (which steer a valve)