Metering and Billing Systems

From energypedia
Revision as of 09:48, 5 August 2009 by ***** (***** | *****)
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Standard kWh meter

Standard kWh meter. Its price is about 40-50 USD
Digital meter. Its price is about 120-150 USD

Advantages

  • fair and transparent
  • reading less frequent than collection; if customers go to office, there is cost reduction
  • amount and time related tariffs possible (demand steering)

Disadvantages

  • high costs (metering device & reading)
  • dis- and re-connection in case of late payment
  • complicated reading and billing










Pre-paid system with coins or cards

Pre-paid system with coins or cards. Its price is about 40-80 USD

Advantages

  • fair and transparent
  • no meter reading
  • no overdue costs
  • no costs for dis- and re-connection
  • close to “ability to pay”-variations
  • coins less expensive than cards

Disadvantages

  • relatively high cost for metering device
  • less forgery proof
  • costs for re-collection of coins and selling system for coins/cards


Current limiter

Current limiter. The price may be less than 5 USD
Current limiter

Advantages

  • simultaneously protecting against overcurrent (actual purpose)
  • delimiting peak demand
  • no meter reading required; flat rates according to max. amperage

Disadvantages

  • danger of fraud and theft of switch fuses
  • additional costs for replacement of cut out fuses
  • time of usage not considered; less fair








Flat rate

Advantages

  • very cheap (no metering or delimiting device)
  • especially in rural areas of Indonesia quite common and accepted
  • can be combined with number of appliances or installed wattage (social control)

Disadvantages

  • provokes waste of electricity, no incentive for saving
  • no load control / demand steering possible (peaks)
  • less fair


Experience form Nepal : Innovative Metering


⇒ Back to Solar Section

⇒ Back to Hydro Section