Difference between revisions of "Energy for Rural Health Centers"
***** (***** | *****) m |
***** (***** | *****) m |
||
Line 32: | Line 32: | ||
Health clinics are generally larger than health posts and employ one or more full-time nurses. Clinics may also employ a part-time physician, depending on the size and location. A health clinic offers a wider array of services than a health post and will possess equipment allowing for more sophisticated diagnoses. Rural health clinics generally fall into one of three categories (Categories I, II and III - see table below) based on the type and number of medical devices used in the facility and the frequency with which they are used on a daily basis. Local resources may make specific energy options more or less advantageous in each location. The categories are listed on page five. Other types of health facilities that require reliable and sustainable electrification include blood banks, stand-alone laboratories and pharmacies, and anti-retroviral treatment (ARV) clinics. Blood banks, stand-alone labs, and pharmacies will, depending on their size, utilize equipment similar to that found in Category I or II Health Clinics and will have similar energy needs. ARV clinics will have significant energy demands similar to those found in a Category III Health Clinic or higher. Energy requirements could be intensive for some ARV clinics due to the computer technology and additional equipment required to perform rapid blood analyses. | Health clinics are generally larger than health posts and employ one or more full-time nurses. Clinics may also employ a part-time physician, depending on the size and location. A health clinic offers a wider array of services than a health post and will possess equipment allowing for more sophisticated diagnoses. Rural health clinics generally fall into one of three categories (Categories I, II and III - see table below) based on the type and number of medical devices used in the facility and the frequency with which they are used on a daily basis. Local resources may make specific energy options more or less advantageous in each location. The categories are listed on page five. Other types of health facilities that require reliable and sustainable electrification include blood banks, stand-alone laboratories and pharmacies, and anti-retroviral treatment (ARV) clinics. Blood banks, stand-alone labs, and pharmacies will, depending on their size, utilize equipment similar to that found in Category I or II Health Clinics and will have similar energy needs. ARV clinics will have significant energy demands similar to those found in a Category III Health Clinic or higher. Energy requirements could be intensive for some ARV clinics due to the computer technology and additional equipment required to perform rapid blood analyses. | ||
− | + | ||
{| style="width: 754px; height: 87px" cellspacing="1" cellpadding="1" width="754" border="1" | {| style="width: 754px; height: 87px" cellspacing="1" cellpadding="1" width="754" border="1" | ||
Line 69: | Line 69: | ||
|- | |- | ||
| | | | ||
− | Category III | + | Category III |
high energy requirements, 20 - 30 kWh/day | high energy requirements, 20 - 30 kWh/day | ||
| | | | ||
− | *<span>Approximately 120 beds or more</span> | + | *<span>Approximately 120 beds or more</span> |
− | *<span><span>May serve as a regional referral center and coordinate communication between several smaller facilities and hospitals in large cities</span></span> | + | *<span><span>May serve as a regional referral center and coordinate communication between several smaller facilities and hospitals in large cities</span></span> |
− | *<span><span>May need to communicate with remote health centers and hospitals by way of telephone, fax, computer, and Internet</span></span> | + | *<span><span>May need to communicate with remote health centers and hospitals by way of telephone, fax, computer, and Internet</span></span> |
*<span><span>May contain sophisticated diagnostic devices (x-ray machine, CD4 counters, blood typing equipment, etc.) requiring additional power</span></span> | *<span><span>May contain sophisticated diagnostic devices (x-ray machine, CD4 counters, blood typing equipment, etc.) requiring additional power</span></span> | ||
Revision as of 09:36, 23 June 2010
Introduction
Electricity Supply
Stepwise Approach to Electrifying a Health Center
- Identify the Health Center's Current Energy Demands
Identify current energy needs and applications, e.g. for lighting, refrigeration, communication, etc. - Account for Near-Term Change
Determine whether energy demands will change in the near-term. - Establish Target Energy Consumption in kWh/day
Use tools such as the USAID Health Clinic Power System Design Tool (4 - Electric Load Inputs) or the Energy Audit Spreadsheet (Worksheet 7 - Future Electric Applications) to calculate the future electric energy consumption in kWh/day. - Determine Technologies Needed to Meet Target
Evaluate energy technologies. - Procure, Design System, and Install Technology
Select the most appropriate energy technology. - Maintain and Financing Your Energy Technology
Institute financing mechanism(s) accounting for operation and maintenance needs and costs.
Remember to contact an expert for assessment, system design, procurement, installation, and maintenance of energy technologies!
Defining Energy Needs
Calculating Energy Needs of a Health Facility
The USAID Health Clinic Power System Design Tool (4 - Electric Load Inputs) and/or the Energy Audit Spreadsheet (Worksheet 7 - Future Electric Applications) as well as the examples of energy demands of typical rural health centers in developing countries can help identifying the overall energy demands of health facilities. The amount of expected energy consumption in kWh/day, in addition to expert consultation, will assisst in the selection of appropriate electrification technology.
Categorization of Health Clinics
The following section describes several types of health facilities. The energy demands of a health facility will be a critical component in the selection of the most appropriate electrification technology. Please note: these descriptions are provided as general comparative guidelines and are not precise descriptions of any one facility.
Health Posts
Health posts are the smallest, most basic health facility. These locations typically will not have a permanent doctor or nurse on staff. The health post may have a full- or part-time primary healthcare provider. Services available at health posts include the treatment of minor illnesses, the tending of minor injuries and, where possible, the provision of basic immunization services. Due to the limited medical equipment used, the overall energy demand of health posts is relatively low. The energy demands of a health post will be satisfied through Category I Health Clinic (see below) electrification options, while taking into account the reduced daily demand for energy.
Health Clinics
Health clinics are generally larger than health posts and employ one or more full-time nurses. Clinics may also employ a part-time physician, depending on the size and location. A health clinic offers a wider array of services than a health post and will possess equipment allowing for more sophisticated diagnoses. Rural health clinics generally fall into one of three categories (Categories I, II and III - see table below) based on the type and number of medical devices used in the facility and the frequency with which they are used on a daily basis. Local resources may make specific energy options more or less advantageous in each location. The categories are listed on page five. Other types of health facilities that require reliable and sustainable electrification include blood banks, stand-alone laboratories and pharmacies, and anti-retroviral treatment (ARV) clinics. Blood banks, stand-alone labs, and pharmacies will, depending on their size, utilize equipment similar to that found in Category I or II Health Clinics and will have similar energy needs. ARV clinics will have significant energy demands similar to those found in a Category III Health Clinic or higher. Energy requirements could be intensive for some ARV clinics due to the computer technology and additional equipment required to perform rapid blood analyses.
Category | Description |
Category I low energy requirements, 5 - 10 kWh/day |
|
Category II moderate energy requirements, 10 - 20 kWh/day |
|
Category III high energy requirements, 20 - 30 kWh/day |
|
Power Generation Options
System Sustainability
Improved Cooking
Further Reading
Powering Health: Electrification Options for Developing Country Health Facilities - USAID website covering all major issues on electricity supply for rural health centers. Several country case studies available. Offers tools for energy audits and load calculation. Highly recommandable!
USAID: Powering Health: Electrification Options for Rural Health Centers - Step-by-step guide on energy needs, power generation options, and sustainability issues for rural health centers. Case studies from Botswana and Uganda.
National Renewable Energy Laboratory (USA) (1998): Renewable Energy for Rural Health Clinics - Publication on energy issues of rural health clinics: energy applications, electrical system components, system selection and economics, institutional considerations. Also provides case studies and lessons learned.
GTZ (1996): Energy Supply for Health Care Facilities in Developing Countries - GTZ publication on energy sources, energy requirements and energy management for rural health centers.
Practical Action: Solar PV Refrigeration of Vaccines - Technical Background of solar refrigeration
References
- ↑ USAID: Powering Health. Internet: http://pdf.usaid.gov/pdf_docs/PNADJ557.pdf