Difference between revisions of "PicoPV Test"

From energypedia
***** (***** | *****)
***** (***** | *****)
m
 
(3 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
+
[[Portal:Solar|►Back to Solar Portal]]
 
= Overview =
 
= Overview =
  
Pico PV Systems has emerged as a strong contender in the solar market of Developing countries . Thus,[[Energising_Development_(EnDev)|EnDev]] has developed a test series to test its effectiveness.
+
Pico PV Systems have emerged as a strong contender in the solar market of developing countries. Thus,[[Energising_Development_(EnDev)|EnDev]] has developed a test series to test their effectiveness.<br/>
#[[PicoPV Test#Technical Test I|Technical Test I]]
 
#[[PicoPV Test#Technical Test II|Technical Test II]]
 
#[[PicoPV Test#Field Test|Field Tests]]
 
 
 
<br/>
 
  
 
== Technical Test I<br/> ==
 
== Technical Test I<br/> ==
Line 14: Line 9:
  
 
<u>These systems were in detail:</u>
 
<u>These systems were in detail:</u>
 +
 
*GL9000SW, Global Marketing Technologies Inc. (US) --> overall picture bad
 
*GL9000SW, Global Marketing Technologies Inc. (US) --> overall picture bad
 
*MS01, Macro-Solar Technology Co,. Ltd (China) --> overall picture very bad
 
*MS01, Macro-Solar Technology Co,. Ltd (China) --> overall picture very bad
Line 37: Line 33:
 
'''Testcriteria Level 2'''
 
'''Testcriteria Level 2'''
  
{| style="width: 70%; width: 100%" border="1" cellpadding="3" cellspacing="0"
+
{| cellspacing="0" cellpadding="3" border="1" style="width: 70%; width: 100%"
 
|-
 
|-
 
|  
 
|  
Line 48: Line 44:
 
| <div class="draft"></div>Battery<br/>
 
| <div class="draft"></div>Battery<br/>
 
|  
 
|  
Measure of capacity (NiMH+ Pb), persistence against overcharging (NiMH), simple durability test (NiMH)<span style="font-size: 11pt; font-family: arial"></span>
+
Measure of capacity (NiMH+ Pb), persistence against overcharging (NiMH), simple durability test (NiMH)<span style="font-size: 11pt; font-family: arial"></span>
  
 
|-
 
|-
 
|  
 
|  
Luminous fux<span style="font-size: 11pt; font-family: arial"></span>
+
Luminous fux<span style="font-size: 11pt; font-family: arial"></span>
  
 
|  
 
|  
Line 62: Line 58:
  
 
|  
 
|  
The duration is measured until luminous flux falls to 70 % of the initial value. (beginning from a fully-charged battery)
+
The duration is measured until luminous flux falls to 70&nbsp;% of the initial value. (beginning from a fully-charged battery)
  
 
|-
 
|-
Line 99: Line 95:
 
== Field Test<br/> ==
 
== Field Test<br/> ==
  
<u><span class="MsoPageNumber"><span style="font-size: 10pt; font-family: 'arial','sans-serif'">The publication is available in English and German:</span></span></u>
+
<u><span class="MsoPageNumber"><span style="font-size: 10pt; font-family: 'arial','sans-serif'">The publication is available in English and German:</span></span></u>
*[[:File:Gtz solar lanterns test.pdf|English version]]
+
 
*[[:File:Gtz solarleuchtentest.pdf|German version]]<span class="MsoPageNumber"><span style="font-size: 10pt; font-family: 'arial','sans-serif'"></span></span>
+
*[[:File:Solar Lanterns Test - Shades of Light.pdf|English version]]
 +
*[[:File:Solarleuchtentest - Licht und Schatten.pdf|German version]]<span class="MsoPageNumber"><span style="font-size: 10pt; font-family: 'arial','sans-serif'"></span></span>
  
 
<br/>
 
<br/>
 +
  
 
= Further Information =
 
= Further Information =

Latest revision as of 09:38, 1 August 2018

►Back to Solar Portal

Overview

Pico PV Systems have emerged as a strong contender in the solar market of developing countries. Thus,EnDev has developed a test series to test their effectiveness.

Technical Test I

The technical tests are performed by Fraunhofer Gesellschaft (FhG/ISE) in Freiburg, Germany. In the first test phase (2007/ 10 - 2008/ 01) twelve systems were tested on road capability with special focus on mechanical stability, lighting characteristics and operability.

These systems were in detail:

  • GL9000SW, Global Marketing Technologies Inc. (US) --> overall picture bad
  • MS01, Macro-Solar Technology Co,. Ltd (China) --> overall picture very bad
  • Solar 2007-1, Solarprojekt-Freilassing e.v. (Germany) --> overall picture good
  • Mightylight, Cosmos Ignite Innovations (India) --> overall picture good
  • AISHWARYA, Noble energy Solar Technologies Ltd. (?) --> overall picture middle
  • Solar Home System, "Afghanistan" --> overall picture very bad
  • 2212SL Wuara, SolEnergy Africa (PTY) Ltd (South Africa) --> overall picture very bad
  • SOLUX-LED-100, SOLUX e.v. (Germany) --> overall picture middle
  • Sun x-set mobile, Würth Solergy (Germany) --> overall picture middle - bad
  • Glowstar GS7, Sollatek Ltd. (UK) --> overall picture middle
  • AS018, Astral Solar technology Co. (China) --> overall picture bad
  • SOLUX-LED-50, SOLUX e.v. (Germany) --> overall picture middle


Technical Test II

Seven solar lanterns reached the second testing stage, of which four are German-made: the Solux LED 100 and Solux LED 50 of the Solux e.V. development assistance project, the Solar 2007-1 by the Freilassing solar promotion project, and the sun x-set mobile produced by Würth. Other lamps of the main test were the Glowstar GS7 of the British company Sollatek, the A­ishwarya NEST-6543 of the Indian manufacturer Noble Energy and the Mightylight 3040, also Indian made.

In the following table you find a selection of the most important criteria:

Testcriteria Level 2

Solar module

Does the system deliver the nominal rated values of power output, open- circuit voltage and shortcircuit current?

Battery

Measure of capacity (NiMH+ Pb), persistence against overcharging (NiMH), simple durability test (NiMH)

Luminous fux

average of 210 minutes

Brennzeit/autonome Zeit

The duration is measured until luminous flux falls to 70 % of the initial value. (beginning from a fully-charged battery)

Luminous efficacy

average is obtained from a period of 210 minutes, beginning from a fully-charged battery.

Charge Controller

Spannungslevel Ladeschluss-/ Lastabwurfspannung, Eigenverbrauch, Signalisierungen, Schutz vor Entladung durch Modul, Wirkungsgrad

Ballast device

How good is the efficiency of the ballast?

Cycle test / degradation of CFL-lamps

How long do CFL lamps last when subjected to a switching cycle of ‘on’ for 60 seconds, ‘off’ for 150 seconds?

Simulation

Ermittlung der solaren Deckungsrate für 5 Standorte bei einer Brenndauer von täglich 3,5 Stunden


Field Test

The publication is available in English and German:



Further Information