Line 9: | Line 9: | ||
| style="width:12%; background:#27811d; color:#ffffff; text-align:center;" |'''Importance''' | | style="width:12%; background:#27811d; color:#ffffff; text-align:center;" |'''Importance''' | ||
|- | |- | ||
− | | rowspan="8" | | + | | rowspan="8" | Electrical boards and switches |
− | | rowspan="8" colspan="1" | | + | | rowspan="8" colspan="1" | Preventive Maintenance |
− | | | + | | Integrity check and cleaning |
− | | | + | | Skilled Technician |
− | | | + | | Technician Toolkit |
− | | | + | | Semi - annually or Yearly |
− | | | + | | Minimum requirement |
|- | |- | ||
− | | | + | | Check labelling and identification |
− | | | + | | Skilled Technician |
− | | | + | | Technician Toolkit |
− | | | + | | Yearly |
− | | | + | | Minimum requirement |
|- | |- | ||
− | | | + | | Electrical protection (including fuses, surge and others) visual and functional tests |
− | | | + | | Skilled Technician |
− | | | + | | Technician Toolkit |
− | | | + | | Yearly |
− | | | + | | Minimum requirement |
|- | |- | ||
− | | | + | | Checking integrity of cables and state of terminals |
− | | | + | | Skilled Technician |
− | | | + | | Technician Toolkit |
− | | | + | | Semi - annually or Yearly |
− | | | + | | Minimum requirement |
|- | |- | ||
− | | | + | | Measurement inspection |
− | | | + | | Skilled Technician |
− | | | + | | Technician Toolkit |
− | | | + | | Yearly |
− | | | + | | Best practice |
|- | |- | ||
− | | | + | | Thermography inspection |
− | | | + | | Skilled Technician |
− | | | + | | Technician Toolkit |
− | | | + | | Yearly |
− | | | + | | Recommendation |
|- | |- | ||
− | | | + | | Check cable tightening |
− | | | + | | Skilled Technician |
− | | | + | | Technician Toolkit |
− | | | + | | Yearly |
− | | | + | | Minimum requirement |
|- | |- | ||
− | | | + | | Monitoring operation test |
− | | | + | | Skilled Technician |
− | | | + | | Technician Toolkit |
− | | | + | | Yearly |
− | | | + | | Best practice |
|} | |} |
Revision as of 13:50, 17 May 2024
System/ Component | Type of Maintenance | Tasks | Required Expertise | Required Equipment | Frequency of Action | Importance |
Electrical boards and switches | Preventive Maintenance | Integrity check and cleaning | Skilled Technician | Technician Toolkit | Semi - annually or Yearly | Minimum requirement |
Check labelling and identification | Skilled Technician | Technician Toolkit | Yearly | Minimum requirement | ||
Electrical protection (including fuses, surge and others) visual and functional tests | Skilled Technician | Technician Toolkit | Yearly | Minimum requirement | ||
Checking integrity of cables and state of terminals | Skilled Technician | Technician Toolkit | Semi - annually or Yearly | Minimum requirement | ||
Measurement inspection | Skilled Technician | Technician Toolkit | Yearly | Best practice | ||
Thermography inspection | Skilled Technician | Technician Toolkit | Yearly | Recommendation | ||
Check cable tightening | Skilled Technician | Technician Toolkit | Yearly | Minimum requirement | ||
Monitoring operation test | Skilled Technician | Technician Toolkit | Yearly | Best practice |