Difference between revisions of "Design of Photovoltaic (PV) Pumping"

From energypedia
***** (***** | *****)
***** (***** | *****)
Line 15: Line 15:
  
  
'''Determination of Water Supply Need for Domestic Water Supply'''
+
'''Determination of Water Supply Need'''
  
 
According to&nbsp;<ref name="Photovoltaic Pumping Overview">https://energypedia.info/index.php/Photovoltaic_(PV)_Pumping</ref>, there are two distinct application for photovoltaic (PV) pumping system;&nbsp;
 
According to&nbsp;<ref name="Photovoltaic Pumping Overview">https://energypedia.info/index.php/Photovoltaic_(PV)_Pumping</ref>, there are two distinct application for photovoltaic (PV) pumping system;&nbsp;
Line 22: Line 22:
  
 
2. Irrigation water supply
 
2. Irrigation water supply
 +
 +
 +
 +
'''Determination of Water Supply Need (domestic water supply)'''
 +
  
 
For domestic water supply, the first data needed is to estimate the water requirement for one person/day. A good estimate can be found from&nbsp;<ref name="Basic Water Needs for Human Activities">http://www.pacinst.org/reports/basic_water_needs/basic_water_needs.pdf</ref>, that relate how much water required to sustain particular activities. Here is the estimate:
 
For domestic water supply, the first data needed is to estimate the water requirement for one person/day. A good estimate can be found from&nbsp;<ref name="Basic Water Needs for Human Activities">http://www.pacinst.org/reports/basic_water_needs/basic_water_needs.pdf</ref>, that relate how much water required to sustain particular activities. Here is the estimate:
Line 39: Line 44:
 
Total &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 50
 
Total &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 50
  
 +
 +
 +
For example, if there are a village with basic need of drinking water, bathing and sanitary services but no need for cooking; then it will require 5+20+15=40 liter/person/day. If the population is 300 persons, then the entire village will require 300 x 40 = 12 000 liter/day. Normally to compensate for water leakage on piping or distribution, 20% additional water will be required then the village will require 14 400 liter/day or 14.4 m3/day.&nbsp;
 +
 +
 +
 +
'''Calculation of Pumping Head'''
 +
 +
Pumping head is normally measured in meter (m), so sometimes there are misconception that pumping head is equal to pumping elevation. In actual, pumping head is divided into three components: elevation head, major losses head, and minor losses head.
 +
 +
Pumping Head (m) = Elevation Head (m) + Major Losses Head (m) + Minor Losses Head (m)
 +
 +
1. Elevation head is measured from the water source surface level to the point of outlet pipe level.
 +
 +
2. Major losses head is influenced by water flow rate, diameter of pipe, length of pipe, and type of pipe (PVC, HDPE etc)
 +
 +
3. Minor losses head is influenced by piping accessories including valve, elbow, inlet pipe etc
 +
 +
The detailed explanation can be found on&nbsp;<ref name="Mathematic of Pumping Water">http://www.raeng.org.uk/education/diploma/maths/pdf/exemplars_advanced/17_pumping_water.pdf</ref>.
  
  
  
 +
'''References'''
  
 
<references />
 
<references />

Revision as of 04:39, 11 October 2012

Introduction

In order to implement cost effective photovoltaic (PV) pumping system, it is necessary to follow some basic guidelines to design and size every system component. This page will explain about detailed calculation needed for sizing every system component. The basic step to design photovoltaic (PV) pumping system is:

1. Determination of water supply need

2. Calculation of pumping head

3. Estimation of solar resource

4. Finding appropriate solar pump and inverter

5. Calculation of PV panel required


Determination of Water Supply Need

According to [1], there are two distinct application for photovoltaic (PV) pumping system; 

1. Drinking water supply (domestic water supply)

2. Irrigation water supply


Determination of Water Supply Need (domestic water supply)


For domestic water supply, the first data needed is to estimate the water requirement for one person/day. A good estimate can be found from [2], that relate how much water required to sustain particular activities. Here is the estimate:

Purpose                             Recommended minimum (liter/person/day)

Drinking water                        5 

Sanitary services                  20

Bathing                                15

Cooking and Kitchen             10

                                    _______+

Total                                     50


For example, if there are a village with basic need of drinking water, bathing and sanitary services but no need for cooking; then it will require 5+20+15=40 liter/person/day. If the population is 300 persons, then the entire village will require 300 x 40 = 12 000 liter/day. Normally to compensate for water leakage on piping or distribution, 20% additional water will be required then the village will require 14 400 liter/day or 14.4 m3/day. 


Calculation of Pumping Head

Pumping head is normally measured in meter (m), so sometimes there are misconception that pumping head is equal to pumping elevation. In actual, pumping head is divided into three components: elevation head, major losses head, and minor losses head.

Pumping Head (m) = Elevation Head (m) + Major Losses Head (m) + Minor Losses Head (m)

1. Elevation head is measured from the water source surface level to the point of outlet pipe level.

2. Major losses head is influenced by water flow rate, diameter of pipe, length of pipe, and type of pipe (PVC, HDPE etc)

3. Minor losses head is influenced by piping accessories including valve, elbow, inlet pipe etc

The detailed explanation can be found on [3].


References