Difference between revisions of "PicoPV Test"
***** (***** | *****) |
***** (***** | *****) |
||
Line 3: | Line 3: | ||
Currently engagement concerning Pico PV Systems increases. In order to advance the framework for project development in this field EnDev has effected various activities. One of these is a test series for Pico PV Systems. It is divided into three phases: | Currently engagement concerning Pico PV Systems increases. In order to advance the framework for project development in this field EnDev has effected various activities. One of these is a test series for Pico PV Systems. It is divided into three phases: | ||
− | <br> | + | <br> |
1. Technical Test I | 1. Technical Test I | ||
Line 11: | Line 11: | ||
3. Field Tests | 3. Field Tests | ||
− | <br> | + | <br> |
=== Technical Test I === | === Technical Test I === | ||
Line 29: | Line 29: | ||
*AS018, Astral Solar technology Co. (China) --> overall picture bad | *AS018, Astral Solar technology Co. (China) --> overall picture bad | ||
+ | <br> | ||
− | + | Detailed test description can be inspected here:<br>[http://www.endev.info/index.php?option=com_docman&task=doc_download&gid=4&Itemid=13 Technical Test I (in german)]<br> | |
− | Detailed test description can be inspected here:<br>[http://www.endev.info/index.php?option=com_docman&task=doc_download&gid=4&Itemid=13 Technical Test I (in german)]<br> | ||
=== Technical Test II === | === Technical Test II === | ||
Line 37: | Line 37: | ||
Testkriterien Level 2 | Testkriterien Level 2 | ||
− | {| cellspacing="0" cellpadding="3" width="70% | + | {| cellspacing="0" cellpadding="3" border="1" width="70%" |
|- | |- | ||
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Solarmodul</span> |
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Werden die Nennwerte von Leistung, Leerlaufspannung und Kurzschlussstrom eingehalten?</span> |
|- | |- | ||
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Batterie</span> |
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Messung der Kapazität (NiMH+ Pb), Beständigkeit gegen Überladung (NiMH), einfacher Haltbarkeitstest (NiMH)</span> |
|- | |- | ||
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Lichtstrom</span> |
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Mittelwert über 210 Minuten</span> |
|- | |- | ||
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Brennzeit/autonome Zeit</span> |
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Leuchtdauer bis der Lichtstrom 70% des nach 15 min gemessenen Wertes erreicht hat (Start mit voll geladener Batterie)</span> |
|- | |- | ||
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Lichtausbeute</span> |
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Mittelwert über 210 min., Start mit voll geladener Batterie</span> |
|- | |- | ||
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Laderegler</span> |
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Spannungslevel Ladeschluss-/ Lastabwurfspannung, Eigenverbrauch, Signalisierungen, Schutz vor Entladung durch Modul, Wirkungsgrad</span> |
|- | |- | ||
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Vorschaltgerät</span> |
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Elektrischer Wirkungsgrad</span> |
|- | |- | ||
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Zyklentest bei CFL-Leuchten</span> |
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Test der Schaltfestigkeit der Leuchte mit dem Zyklus 60s an 150s aus</span> |
|- | |- | ||
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Simulation</span> |
− | | <span style="font-size: 11pt; font-family: arial; | + | | <span style="font-size: 11pt; font-family: arial;">Ermittlung der solaren Deckungsrate für 5 Standorte bei einer Brenndauer von täglich 3,5 Stunden</span> |
|} | |} | ||
+ | <br> | ||
− | + | <br> | |
− | |||
Detailed test description can be inspected here:<br>[http://www.endev.info/index.php?option=com_docman&task=doc_download&gid=334 Technical Test II] (german) | Detailed test description can be inspected here:<br>[http://www.endev.info/index.php?option=com_docman&task=doc_download&gid=334 Technical Test II] (german) | ||
Line 76: | Line 76: | ||
not yet started | not yet started | ||
+ | |||
+ | |||
+ | [[Category: Solar]] |
Revision as of 11:57, 3 February 2009
Pico PV Systems
Currently engagement concerning Pico PV Systems increases. In order to advance the framework for project development in this field EnDev has effected various activities. One of these is a test series for Pico PV Systems. It is divided into three phases:
1. Technical Test I
2. Technical Test II
3. Field Tests
Technical Test I
The technical tests are performed by Fraunhofer Gesellschaft FhG/ISE in Freiburg, Germany. In the first test phase (2007/ 10 - 2008/ 01) eleven systems were tested on road capability with special focus on mechanical stability, lighting characteristics and operability. These systems were in detail:
- GL9000SW, Global Marketing Technologies Inc. (US) --> overall picture bad
- MS01, Macro-Solar Technology Co,. Ltd (China) --> overall picture very bad
- Solar 2007-1, Solarprojekt-Freilassing e.v. (Germany) --> overall picture good
- Mightylight, Cosmos Ignite Innovations (India) --> overall picture good
- AISHWARYA, Noble energy Solar Technologies Ltd. (?) --> overall picture middle
- Solar Home System, "Afghanistan" --> overall picture very bad
- 2212SL Wuara, SolEnergy Africa (PTY) Ltd (South Africa) --> overall picture very bad
- SOLUX-LED-100, SOLUX e.v. (Germany) --> overall picture middle
- Sun x-set mobile, Würth Solergy (Germany) --> overall picture middle - bad
- Glowstar GS7, Sollatek Ltd. (UK) --> overall picture middle
- AS018, Astral Solar technology Co. (China) --> overall picture bad
Detailed test description can be inspected here:
Technical Test I (in german)
Technical Test II
Testkriterien Level 2
Solarmodul | Werden die Nennwerte von Leistung, Leerlaufspannung und Kurzschlussstrom eingehalten? |
Batterie | Messung der Kapazität (NiMH+ Pb), Beständigkeit gegen Überladung (NiMH), einfacher Haltbarkeitstest (NiMH) |
Lichtstrom | Mittelwert über 210 Minuten |
Brennzeit/autonome Zeit | Leuchtdauer bis der Lichtstrom 70% des nach 15 min gemessenen Wertes erreicht hat (Start mit voll geladener Batterie) |
Lichtausbeute | Mittelwert über 210 min., Start mit voll geladener Batterie |
Laderegler | Spannungslevel Ladeschluss-/ Lastabwurfspannung, Eigenverbrauch, Signalisierungen, Schutz vor Entladung durch Modul, Wirkungsgrad |
Vorschaltgerät | Elektrischer Wirkungsgrad |
Zyklentest bei CFL-Leuchten | Test der Schaltfestigkeit der Leuchte mit dem Zyklus 60s an 150s aus |
Simulation | Ermittlung der solaren Deckungsrate für 5 Standorte bei einer Brenndauer von täglich 3,5 Stunden |
Detailed test description can be inspected here:
Technical Test II (german)
Field Test
not yet started