Knowledge fuels change - Support energypedia!
For over 10 years, energypedia has been connecting energy experts around the world — helping them share knowledge, learn from each other, and accelerate the global energy transition.
Today, we ask for your support to keep this platform free and accessible to all.
Even a small contribution makes a big difference! If just 10–20% of our 60,000+ monthly visitors donated the equivalent of a cup of coffee — €5 — Energypedia would be fully funded for a whole year.
Is the knowledge you’ve gained through Energypedia this year worth €5 or more?
Your donation keeps the platform running, helps us create new knowledge products, and contributes directly to achieving SDG 7.
Thank you for your support, your donation, big or small, truly matters!
Difference between revisions of "MHP La Laguna"
***** (***** | *****) |
***** (***** | *****) m |
||
| (5 intermediate revisions by 2 users not shown) | |||
| Line 5: | Line 5: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Name of the site:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Name of the site:</span> | ||
| − | | style="width: 390px;" | | + | | style="width: 390px;" | La Laguna |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Country:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Country:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;">Nicaragua (GPS Coordinates: ?)</span> | + | | style="width: 390px;" | <span style="line-height: 18px;">[[Nicaragua_Energy_Situation|Nicaragua]] (GPS Coordinates: ?)</span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Type:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Turbine Type:</span> | ||
| Line 14: | Line 14: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Power Output:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Power Output:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"> | + | | style="width: 390px;" | <span style="line-height: 18px;">54 kW</span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Project Status:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Project Status:</span> | ||
| Line 33: | Line 33: | ||
{| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;" | {| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;" | ||
|- | |- | ||
| − | | style="width: | + | | style="width: 243px;" | <span style="line-height: 18px;">Gross Head:</span> |
| − | | style="width: | + | | style="width: 341px;" | |
| + | 47m (GPS data<span style="line-height: 1.5em;">)</span> | ||
| + | |||
|- | |- | ||
| − | | style="width: | + | | style="width: 243px;" | <span style="line-height: 18px;">Net/Design Head:</span> |
| − | | style="width: | + | | style="width: 341px;" | -<span style="line-height: 18px;"></span> |
|- | |- | ||
| − | | style="width: | + | | style="width: 243px;" | <span style="line-height: 18px;">Flow (design flow):</span> |
| − | | style="width: | + | | style="width: 341px;" | -<span style="line-height: 18px;"></span> |
|- | |- | ||
| − | | style="width: | + | | style="width: 243px;" | <span style="line-height: 18px;">Comments on flow variation during the year:</span> |
| − | | style="width: | + | | style="width: 341px;" | -<span style="line-height: 18px;"></span> |
|} | |} | ||
| Line 57: | Line 59: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Comments:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Comments:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"> | + | | style="width: 390px;" | <span style="line-height: 18px;">-</span> |
|} | |} | ||
| Line 70: | Line 72: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Dam Dimensions:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Dam Dimensions:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"></span> | + | | style="width: 390px;" | -<span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Storage Volume Reservoir:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Storage Volume Reservoir:</span> | ||
| − | | style="width: 390px;" | | + | | style="width: 390px;" | - |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Sedimentation Basin material:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Sedimentation Basin material:</span> | ||
| Line 79: | Line 81: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Sedimentation Basin Dimensions:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Sedimentation Basin Dimensions:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"></span> | + | | style="width: 390px;" | -<span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Length:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Penstock Length:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"></span> | + | | style="width: 390px;" | 700m<span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Diameter at Beginning:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Penstock Diameter at Beginning:</span> | ||
| − | | style="width: 390px;" | | + | | style="width: 390px;" | 10" |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Diameter at End:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Penstock Diameter at End:</span> | ||
| − | | style="width: 390px;" | | + | | style="width: 390px;" | 8" |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Changes of Diameter:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Penstock Changes of Diameter:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"></span> | + | | style="width: 390px;" | 1<span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Material:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Penstock Material:</span> | ||
| Line 97: | Line 99: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Security Valve:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Security Valve:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"></span> | + | | style="width: 390px;" | 8"<span style="line-height: 18px;"></span> |
|} | |} | ||
| Line 107: | Line 109: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Type:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Turbine Type:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;">Pelton, | + | | style="width: 390px;" | <span style="line-height: 18px;">Pelton, 2 injectors</span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Diameter:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Turbine Diameter:</span> | ||
| − | | style="width: 390px;" | | + | | style="width: 390px;" | - |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Material:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Turbine Material:</span> | ||
| − | | style="width: 390px;" | | + | | style="width: 390px;" | Bronze |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Manufacturer:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Turbine Manufacturer:</span> | ||
| Line 119: | Line 121: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Potencial (nominal):</span> | | style="width: 194px;" | <span style="line-height: 18px;">Potencial (nominal):</span> | ||
| − | | style="width: 390px;" | | + | | style="width: 390px;" | <br/><span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Rated Head:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Rated Head:</span> | ||
| Line 148: | Line 150: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Generator Manufacturer and Model:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Generator Manufacturer and Model:</span> | ||
| − | | style="width: 390px;" | | + | | style="width: 390px;" | OGI, LLC<span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Phases:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Phases:</span> | ||
| Line 154: | Line 156: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Potencial (nominal):</span> | | style="width: 194px;" | <span style="line-height: 18px;">Potencial (nominal):</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"></span> | + | | style="width: 390px;" | 20kW (30kvA)<span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Nominal voltage:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Nominal voltage:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"></span> | + | | style="width: 390px;" | 480 v, singlephase<span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Nominal Speed:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Nominal Speed:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"></span> | + | | style="width: 390px;" | 1800rpm<span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Frequency:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Frequency:</span> | ||
| Line 166: | Line 168: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Isolation Class:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Isolation Class:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"></span> | + | | style="width: 390px;" | H<span style="line-height: 18px;"></span> |
|} | |} | ||
| Line 174: | Line 176: | ||
|- | |- | ||
| style="width: 190px;" | <span style="line-height: 18px;">Type of Belt:</span> | | style="width: 190px;" | <span style="line-height: 18px;">Type of Belt:</span> | ||
| − | | style="width: 394px;" | <span style="line-height: 18px;"></span> | + | | style="width: 394px;" | Abasic plana<span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 190px;" | <span style="line-height: 18px;">Belt Manufacturer:</span> | | style="width: 190px;" | <span style="line-height: 18px;">Belt Manufacturer:</span> | ||
| − | | style="width: 394px;" | | + | | style="width: 394px;" | Central de Rodamiento |
|- | |- | ||
| style="width: 190px;" | <span style="line-height: 18px;">Distance between Pulleys:</span> | | style="width: 190px;" | <span style="line-height: 18px;">Distance between Pulleys:</span> | ||
| − | | style="width: 394px;" | <span style="line-height: 18px;"></span> | + | | style="width: 394px;" | -<span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 190px;" | <span style="line-height: 18px;">Diameter of Generator Pulley:</span> | | style="width: 190px;" | <span style="line-height: 18px;">Diameter of Generator Pulley:</span> | ||
| − | | style="width: 394px;" | <span style="line-height: 18px;"></span> | + | | style="width: 394px;" | -<span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 190px;" | <span style="line-height: 18px;">Diameter of Generator Pulley:</span> | | style="width: 190px;" | <span style="line-height: 18px;">Diameter of Generator Pulley:</span> | ||
| − | | style="width: 394px;" | <span style="line-height: 18px;"></span> | + | | style="width: 394px;" | -<span style="line-height: 18px;"></span> |
|} | |} | ||
| Line 194: | Line 196: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Control System Manufacturer and Model:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Control System Manufacturer and Model:</span> | ||
| − | | style="width: 390px;" | Thomson and Howe Energy Systems, | + | | style="width: 390px;" | Thomson and Howe Energy Systems, A2<span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Type of Control:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Type of Control:</span> | ||
| Line 200: | Line 202: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Capacity:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Capacity:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"></span> | + | | style="width: 390px;" | 30kW<span style="line-height: 18px;"></span> |
|} | |} | ||
| Line 216: | Line 218: | ||
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Grid Voltage:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Grid Voltage:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"></span> | + | | style="width: 390px;" | 480V<span style="line-height: 18px;"></span> |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Diameter of Conductor:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Diameter of Conductor:</span> | ||
| − | | style="width: 390px;" | | + | | style="width: 390px;" | 4x 1/0 |
|- | |- | ||
| style="width: 194px;" | <span style="line-height: 18px;">Transformer Rating:</span> | | style="width: 194px;" | <span style="line-height: 18px;">Transformer Rating:</span> | ||
| − | | style="width: 390px;" | <span style="line-height: 18px;"></span> | + | | style="width: 390px;" | -<span style="line-height: 18px;"></span> |
|} | |} | ||
| Line 267: | Line 269: | ||
<br/> | <br/> | ||
| + | <br/> | ||
| + | |||
| + | <br/> | ||
= Project Photos<br/> = | = Project Photos<br/> = | ||
| Line 275: | Line 280: | ||
| [[File:Dam La Laguna.JPG|thumb|300px|alt=Dam La Laguna.JPG]] | | [[File:Dam La Laguna.JPG|thumb|300px|alt=Dam La Laguna.JPG]] | ||
|- | |- | ||
| − | | [[File: | + | | [[File:Penstock La Laguna 2.JPG|thumb|300px|alt=Penstock La Laguna 2.JPG]] |
| − | | [[File:Turbine La Laguna.JPG|300px| | + | | [[File:Turbine La Laguna.JPG|thumb|300px|alt=Turbine La Laguna.JPG]] |
|- | |- | ||
| − | | [[File: | + | | [[File:Injection La Laguna.JPG|thumb|300px|alt=Injection La Laguna.JPG]] |
| | | | ||
|} | |} | ||
<br/><br/> | <br/><br/> | ||
| + | |||
| + | [[Category:Micro_Hydro]] | ||
Latest revision as of 09:55, 17 July 2014
Overview
| Name of the site: | La Laguna |
| Country: | Nicaragua (GPS Coordinates: ?) |
| Turbine Type: | Pelton |
| Power Output: | 54 kW |
| Project Status: | in operation |
| Comments: | - |
Operation Data
| Gross Head: |
47m (GPS data) |
| Net/Design Head: | - |
| Flow (design flow): | - |
| Comments on flow variation during the year: | - |
Technical Information
| Comments: | - |
Civil Works and Penstock
| Dam construction material: | Concrete |
| Dam Dimensions: | - |
| Storage Volume Reservoir: | - |
| Sedimentation Basin material: | Concrete |
| Sedimentation Basin Dimensions: | - |
| Penstock Length: | 700m |
| Penstock Diameter at Beginning: | 10" |
| Penstock Diameter at End: | 8" |
| Penstock Changes of Diameter: | 1 |
| Penstock Material: | PVC |
| Security Valve: | 8" |
Electromechanical Equipment
Turbine
| Turbine Type: | Pelton, 2 injectors |
| Turbine Diameter: | - |
| Turbine Material: | Bronze |
| Turbine Manufacturer: | Nica Bosch (Contact: company does not exist any more) |
| Potencial (nominal): | |
| Rated Head: | |
| Rated Flow: | |
| Rated Speed: | |
| Runaway Speed: | |
| Shaft diameter and material: | |
| Direction of Rotation: | clockwise |
| Orientation of Shaft: | horizontal |
Generator:
| Generator Manufacturer and Model: | OGI, LLC |
| Phases: | 3 |
| Potencial (nominal): | 20kW (30kvA) |
| Nominal voltage: | 480 v, singlephase |
| Nominal Speed: | 1800rpm |
| Frequency: | 60 Hz |
| Isolation Class: | H |
Mechanical Transmission / Coupling
| Type of Belt: | Abasic plana |
| Belt Manufacturer: | Central de Rodamiento |
| Distance between Pulleys: | - |
| Diameter of Generator Pulley: | - |
| Diameter of Generator Pulley: | - |
Control System
| Control System Manufacturer and Model: | Thomson and Howe Energy Systems, A2 |
| Type of Control: | Load Control |
| Capacity: | 30kW |
Electrical Transmission
| Mini Grid: | yes |
| Connection to national Grid: | no |
| Grid Voltage: | 480V |
| Diameter of Conductor: | 4x 1/0 |
| Transformer Rating: | - |
Economic Information
| Developer: (Contact: ) | |
| Start of Construction: | |
| Date of Commissioning: | |
| Ownership / Operation Model: | |
| Operator: | |
| Tariff structure: | |
| Connected Housholds: | 25 |
| Connection Cost Cost to be covered by houshold: | |
| Overall Project Costs: |
Project Photos



















