Difference between revisions of "MHP La Laguna"

From energypedia
***** (***** | *****)
***** (***** | *****)
m
 
(4 intermediate revisions by 2 users not shown)
Line 5: Line 5:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Name of the site:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Name of the site:</span>
| style="width: 390px;" | El Plan
+
| style="width: 390px;" | La Laguna
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Country:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Country:</span>
| style="width: 390px;" | <span style="line-height: 18px;">Nicaragua (GPS Coordinates: ?)</span>
+
| style="width: 390px;" | <span style="line-height: 18px;">[[Nicaragua_Energy_Situation|Nicaragua]] (GPS Coordinates: ?)</span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Type:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Type:</span>
Line 14: Line 14:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Power Output:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Power Output:</span>
| style="width: 390px;" | <span style="line-height: 18px;">24 kW</span>
+
| style="width: 390px;" | <span style="line-height: 18px;">54 kW</span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Project Status:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Project Status:</span>
Line 33: Line 33:
 
{| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;"
 
{| border="0" align="left" cellspacing="1" cellpadding="2" style="width: 600px;"
 
|-
 
|-
| style="width: 194px;" | <span style="line-height: 18px;">Gross Head:</span>
+
| style="width: 243px;" | <span style="line-height: 18px;">Gross Head:</span>
| style="width: 390px;" | 200m<span style="line-height: 18px;"></span>
+
| style="width: 341px;" |  
 +
47m (GPS data<span style="line-height: 1.5em;">)</span>
 +
 
 
|-
 
|-
| style="width: 194px;" | <span style="line-height: 18px;">Net/Design Head:</span>
+
| style="width: 243px;" | <span style="line-height: 18px;">Net/Design Head:</span>
| style="width: 390px;" | 200m<span style="line-height: 18px;"></span>
+
| style="width: 341px;" | -<span style="line-height: 18px;"></span>
 
|-
 
|-
| style="width: 194px;" | <span style="line-height: 18px;">Flow (design flow):</span>
+
| style="width: 243px;" | <span style="line-height: 18px;">Flow (design flow):</span>
| style="width: 390px;" | 20 l/s<span style="line-height: 18px;"></span>
+
| style="width: 341px;" | -<span style="line-height: 18px;"></span>
 
|-
 
|-
| style="width: 290px;" | <span style="line-height: 18px;">Comments on flow variation during the year:</span>
+
| style="width: 243px;" | <span style="line-height: 18px;">Comments on flow variation during the year:</span>
| style="width: 294px;" | Problems with flow during dry season.<span style="line-height: 18px;"></span>
+
| style="width: 341px;" | -<span style="line-height: 18px;"></span>
 
|}
 
|}
  
Line 57: Line 59:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Comments:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Comments:</span>
| style="width: 390px;" | <span style="line-height: 18px;">General Technical Comments on the Project</span>
+
| style="width: 390px;" | <span style="line-height: 18px;">-</span>
 
|}
 
|}
  
Line 70: Line 72:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Dam Dimensions:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Dam Dimensions:</span>
| style="width: 390px;" | <span style="line-height: 18px;"></span>
+
| style="width: 390px;" | -<span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Storage Volume Reservoir:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Storage Volume Reservoir:</span>
| style="width: 390px;" | <br/>
+
| style="width: 390px;" | -
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Sedimentation Basin material:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Sedimentation Basin material:</span>
Line 79: Line 81:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Sedimentation Basin Dimensions:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Sedimentation Basin Dimensions:</span>
| style="width: 390px;" | <span style="line-height: 18px;"></span>
+
| style="width: 390px;" | -<span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Length:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Length:</span>
| style="width: 390px;" | <span style="line-height: 18px;"></span>
+
| style="width: 390px;" | 700m<span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Diameter at Beginning:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Diameter at Beginning:</span>
| style="width: 390px;" | <br/>
+
| style="width: 390px;" | 10"
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Diameter at End:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Diameter at End:</span>
| style="width: 390px;" | <br/>
+
| style="width: 390px;" | 8"
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Changes of Diameter:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Changes of Diameter:</span>
| style="width: 390px;" | <span style="line-height: 18px;"></span>
+
| style="width: 390px;" | 1<span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Material:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Penstock Material:</span>
Line 97: Line 99:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Security Valve:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Security Valve:</span>
| style="width: 390px;" | <span style="line-height: 18px;"></span>
+
| style="width: 390px;" | 8"<span style="line-height: 18px;"></span>
 
|}
 
|}
  
Line 107: Line 109:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Type:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Type:</span>
| style="width: 390px;" | <span style="line-height: 18px;">Pelton, 1 injector</span>
+
| style="width: 390px;" | <span style="line-height: 18px;">Pelton, 2 injectors</span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Diameter:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Diameter:</span>
| style="width: 390px;" | <br/>
+
| style="width: 390px;" | -
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Material:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Material:</span>
| style="width: 390px;" | <br/>
+
| style="width: 390px;" | Bronze
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Manufacturer:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Turbine Manufacturer:</span>
Line 119: Line 121:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Potencial (nominal):</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Potencial (nominal):</span>
| style="width: 390px;" | 24 kW<span style="line-height: 18px;"></span>
+
| style="width: 390px;" | <br/><span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Rated Head:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Rated Head:</span>
Line 148: Line 150:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Generator Manufacturer and Model:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Generator Manufacturer and Model:</span>
| style="width: 390px;" | Stamford<span style="line-height: 18px;"></span>
+
| style="width: 390px;" | OGI, LLC<span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Phases:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Phases:</span>
Line 154: Line 156:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Potencial (nominal):</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Potencial (nominal):</span>
| style="width: 390px;" | <span style="line-height: 18px;"></span>
+
| style="width: 390px;" | 20kW (30kvA)<span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Nominal voltage:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Nominal voltage:</span>
| style="width: 390px;" | <span style="line-height: 18px;"></span>
+
| style="width: 390px;" | 480 v, singlephase<span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Nominal Speed:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Nominal Speed:</span>
| style="width: 390px;" | <span style="line-height: 18px;"></span>
+
| style="width: 390px;" | 1800rpm<span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Frequency:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Frequency:</span>
Line 166: Line 168:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Isolation Class:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Isolation Class:</span>
| style="width: 390px;" | <span style="line-height: 18px;"></span>
+
| style="width: 390px;" | H<span style="line-height: 18px;"></span>
 
|}
 
|}
  
Line 174: Line 176:
 
|-
 
|-
 
| style="width: 190px;" | <span style="line-height: 18px;">Type of Belt:</span>
 
| style="width: 190px;" | <span style="line-height: 18px;">Type of Belt:</span>
| style="width: 394px;" | <span style="line-height: 18px;"></span>
+
| style="width: 394px;" | Abasic plana<span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 190px;" | <span style="line-height: 18px;">Belt Manufacturer:</span>
 
| style="width: 190px;" | <span style="line-height: 18px;">Belt Manufacturer:</span>
| style="width: 394px;" | <br/>
+
| style="width: 394px;" | Central de Rodamiento
 
|-
 
|-
 
| style="width: 190px;" | <span style="line-height: 18px;">Distance between Pulleys:</span>
 
| style="width: 190px;" | <span style="line-height: 18px;">Distance between Pulleys:</span>
| style="width: 394px;" | <span style="line-height: 18px;"></span>
+
| style="width: 394px;" | -<span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 190px;" | <span style="line-height: 18px;">Diameter of Generator Pulley:</span>
 
| style="width: 190px;" | <span style="line-height: 18px;">Diameter of Generator Pulley:</span>
| style="width: 394px;" | <span style="line-height: 18px;"></span>
+
| style="width: 394px;" | -<span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 190px;" | <span style="line-height: 18px;">Diameter of Generator Pulley:</span>
 
| style="width: 190px;" | <span style="line-height: 18px;">Diameter of Generator Pulley:</span>
| style="width: 394px;" | <span style="line-height: 18px;"></span>
+
| style="width: 394px;" | -<span style="line-height: 18px;"></span>
 
|}
 
|}
  
Line 194: Line 196:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Control System Manufacturer and Model:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Control System Manufacturer and Model:</span>
| style="width: 390px;" | Thomson and Howe Energy Systems, J2<span style="line-height: 18px;"></span>
+
| style="width: 390px;" | Thomson and Howe Energy Systems, A2<span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Type of Control:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Type of Control:</span>
Line 200: Line 202:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Capacity:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Capacity:</span>
| style="width: 390px;" | <span style="line-height: 18px;"></span>
+
| style="width: 390px;" | 30kW<span style="line-height: 18px;"></span>
 
|}
 
|}
  
Line 216: Line 218:
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Grid Voltage:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Grid Voltage:</span>
| style="width: 390px;" | <span style="line-height: 18px;"></span>
+
| style="width: 390px;" | 480V<span style="line-height: 18px;"></span>
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Diameter of Conductor:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Diameter of Conductor:</span>
| style="width: 390px;" | <br/>
+
| style="width: 390px;" | 4x 1/0
 
|-
 
|-
 
| style="width: 194px;" | <span style="line-height: 18px;">Transformer Rating:</span>
 
| style="width: 194px;" | <span style="line-height: 18px;">Transformer Rating:</span>
| style="width: 390px;" | <span style="line-height: 18px;"></span>
+
| style="width: 390px;" | -<span style="line-height: 18px;"></span>
 
|}
 
|}
  
Line 267: Line 269:
 
<br/>
 
<br/>
  
 +
<br/>
  
 +
<br/>
  
 
= Project Photos<br/> =
 
= Project Photos<br/> =
Line 276: Line 280:
 
| [[File:Dam La Laguna.JPG|thumb|300px|alt=Dam La Laguna.JPG]]
 
| [[File:Dam La Laguna.JPG|thumb|300px|alt=Dam La Laguna.JPG]]
 
|-
 
|-
| [[File:Penstock La Laguna 2.JPG|300px]]
+
| [[File:Penstock La Laguna 2.JPG|thumb|300px|alt=Penstock La Laguna 2.JPG]]
| [[File:Turbine La Laguna.JPG|300px]]
+
| [[File:Turbine La Laguna.JPG|thumb|300px|alt=Turbine La Laguna.JPG]]
 
|-
 
|-
| [[File:Injection La Laguna.JPG|300px]]
+
| [[File:Injection La Laguna.JPG|thumb|300px|alt=Injection La Laguna.JPG]]
 
|  
 
|  
 
|}
 
|}
  
 
<br/><br/>
 
<br/><br/>
 +
 +
[[Category:Micro_Hydro]]

Latest revision as of 09:55, 17 July 2014

Overview

Name of the site: La Laguna
Country: Nicaragua (GPS Coordinates: ?)
Turbine Type: Pelton
Power Output: 54 kW
Project Status: in operation
Comments: -




Operation Data

Gross Head:

47m (GPS data)

Net/Design Head: -
Flow (design flow): -
Comments on flow variation during the year: -




Technical Information

Comments: -


Civil Works and Penstock

Dam construction material: Concrete
Dam Dimensions: -
Storage Volume Reservoir: -
Sedimentation Basin material: Concrete
Sedimentation Basin Dimensions: -
Penstock Length: 700m
Penstock Diameter at Beginning: 10"
Penstock Diameter at End: 8"
Penstock Changes of Diameter: 1
Penstock Material: PVC
Security Valve: 8"

Electromechanical Equipment

Turbine

Turbine Type: Pelton, 2 injectors
Turbine Diameter: -
Turbine Material: Bronze
Turbine Manufacturer: Nica Bosch (Contact: company does not exist any more)
Potencial (nominal):
Rated Head:
Rated Flow:
Rated Speed:
Runaway Speed:
Shaft diameter and material:
Direction of Rotation: clockwise
Orientation of Shaft: horizontal

Generator:

Generator Manufacturer and Model: OGI, LLC
Phases: 3
Potencial (nominal): 20kW (30kvA)
Nominal voltage: 480 v, singlephase
Nominal Speed: 1800rpm
Frequency: 60 Hz
Isolation Class: H

Mechanical Transmission / Coupling

Type of Belt: Abasic plana
Belt Manufacturer: Central de Rodamiento
Distance between Pulleys: -
Diameter of Generator Pulley: -
Diameter of Generator Pulley: -

Control System

Control System Manufacturer and Model: Thomson and Howe Energy Systems, A2
Type of Control: Load Control
Capacity: 30kW


Electrical Transmission

Mini Grid: yes
Connection to national Grid: no
Grid Voltage: 480V
Diameter of Conductor: 4x 1/0
Transformer Rating: -


Economic Information

Developer: (Contact: )
Start of Construction:
Date of Commissioning:
Ownership / Operation Model:
Operator:
Tariff structure:
Connected Housholds: 25
Connection Cost Cost to be covered by houshold:
Overall Project Costs:







Project Photos

Penstock La Laguna.JPG
Dam La Laguna.JPG
Penstock La Laguna 2.JPG
Turbine La Laguna.JPG
Injection La Laguna.JPG