Difference between revisions of "Control Equipment - Hydropower"

From energypedia
***** (***** | *****)
***** (***** | *****)
m
Line 38: Line 38:
 
</v:shape><![endif]--><!--[if !vml]--><!--[endif]--><span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">Function:</span>  ===
 
</v:shape><![endif]--><!--[if !vml]--><!--[endif]--><span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">Function:</span>  ===
  
<span style="display: none;" id="1274973221741E">&nbsp;</span>  
+
<span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">[[Image:Mhp-scheme.jpg|right|560x386px|Elements of a Micro Hydro  Power Scheme]]
 +
</span>
 +
 
 +
===  ===
 +
 
 +
<span id="1274973221741E" style="display: none;">&nbsp;</span>  
  
 
<span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">Load- or Flow- controller
 
<span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">Load- or Flow- controller
Line 47: Line 52:
 
the energy output of a turbine/generator is constant as well. Power
 
the energy output of a turbine/generator is constant as well. Power
 
demand is
 
demand is
usually fluctuating over the time (e.g. day/night). </span><span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">If supply is higher than demand, excess energy is diverted/dumped or the
+
usually fluctuating over the time (e.g. day/night). </span><span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">If supply is higher than demand, excess energy must be diverted, dumped. altrenatively the
flow is reduced. In case of more power demand than supply the controler cuts of
+
water flow can be reduced which results in less power output.</span><br>
the of demand line.&nbsp;</span> <span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">Load controller are placed
+
 
 +
<span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;"> In case of more power demand than supply the controler cuts of
 +
the of demand line.</span><br>
 +
 
 +
<span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">Load controller are placed
 
between generator output and the consumer line. </span><!--EndFragment-->  
 
between generator output and the consumer line. </span><!--EndFragment-->  
  
<span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">[[Image:Mhp-scheme.jpg|right|560x386px|Elements of a Micro Hydro Power Scheme]]
+
<span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">
 
</span>  
 
</span>  
 +
 +
<br>
  
 
<!--[if gte mso 9]><xml>
 
<!--[if gte mso 9]><xml>
<o:shapedefaults v:ext="edit" spidmax="1027"/>
+
<o:shapedefaults v:ext="edit" spidmax="1027"/>
 
</xml><![endif]--><!--[if gte mso 9]><xml>
 
</xml><![endif]--><!--[if gte mso 9]><xml>
<o:shapelayout v:ext="edit">
+
<o:shapelayout v:ext="edit">
  <o:idmap v:ext="edit" data="1"/>
+
<o:idmap v:ext="edit" data="1"/>
</o:shapelayout></xml><![endif]--> <!--StartFragment-->  
+
</o:shapelayout></xml><![endif]--> <!--StartFragment-->
  
 
=== <span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">Controll Elements</span>  ===
 
=== <span lang="DE" style="font-size: 11pt; font-family: Tahoma; color: black;">Controll Elements</span>  ===

Revision as of 15:28, 27 May 2010

Overview:

Function:

Elements of a Micro Hydro Power Scheme

Load- or Flow- controller ensure that the power output does not exceed the power demand (e.g. 230V, 50 Hz).

If flow of water in a MHP-station is constant the energy output of a turbine/generator is constant as well. Power demand is usually fluctuating over the time (e.g. day/night). If supply is higher than demand, excess energy must be diverted, dumped. altrenatively the water flow can be reduced which results in less power output.

In case of more power demand than supply the controler cuts of the of demand line.

Load controller are placed between generator output and the consumer line.



Controll Elements

Load controller

Electronic circuit, which keeps output power constant in Frequency- and Voltage- parameters.

Fluctuating energy demand requires a mechanism which either regulates the water input into the turbine (=> flow control) or  by diverting excess energy from the consumer connection (=>ballast load). 

Flow controll:

regulates the amount of water into the turbine in order to match power output and power demand.

Ballast load:

If energy demand is temporarily low, the controller sends excess energy to the Ballst Load. This are usually electrical heaters in water or air.

  • ..