Currently engagement concerning Pico PV Systems increases. In order to advance the framework for project development in this field EnDev has effected various activities. One of these is a test series for Pico PV Systems. It is divided into three phases:


1. Technical Test I

2. Technical Test II

3. Field Tests


Technical Test I

The technical tests are performed by Fraunhofer Gesellschaft FhG/ISE in Freiburg, Germany. In the first test phase (2007/ 10 - 2008/ 01) eleven systems were tested on road capability with special focus on mechanical stability, lighting characteristics and operability. These systems were in detail:

  • GL9000SW, Global Marketing Technologies Inc. (US) --> overall picture bad
  • MS01, Macro-Solar Technology Co,. Ltd (China) --> overall picture very bad
  • Solar 2007-1, Solarprojekt-Freilassing e.v. (Germany) --> overall picture good
  • Mightylight, Cosmos Ignite Innovations (India) --> overall picture good
  • AISHWARYA, Noble energy Solar Technologies Ltd. (?) --> overall picture middle
  • Solar Home System, "Afghanistan" --> overall picture very bad
  • 2212SL Wuara, SolEnergy Africa (PTY) Ltd (South Africa) --> overall picture very bad
  • SOLUX-LED-100, SOLUX e.v. (Germany) --> overall picture middle
  • Sun x-set mobile, Würth Solergy (Germany) --> overall picture middle - bad
  • Glowstar GS7, Sollatek Ltd. (UK) --> overall picture middle
  • AS018, Astral Solar technology Co. (China) --> overall picture bad


Detailed test description can be inspected here:
Technical Test I (in german)

Technical Test II

Testkriterien Level 2

Solarmodul Werden die Nennwerte von Leistung, Leerlaufspannung und Kurzschlussstrom eingehalten?
Batterie Messung der Kapazität (NiMH+ Pb), Beständigkeit gegen Überladung (NiMH), einfacher Haltbarkeitstest (NiMH)
Lichtstrom Mittelwert über 210 Minuten
Brennzeit/autonome Zeit Leuchtdauer bis der Lichtstrom 70% des nach 15 min gemessenen Wertes erreicht hat (Start mit voll geladener Batterie)
Lichtausbeute Mittelwert über 210 min., Start mit voll geladener Batterie
Laderegler Spannungslevel Ladeschluss-/ Lastabwurfspannung, Eigenverbrauch, Signalisierungen, Schutz vor Entladung durch Modul, Wirkungsgrad
Vorschaltgerät Elektrischer Wirkungsgrad
Zyklentest bei CFL-Leuchten Test der Schaltfestigkeit der Leuchte mit dem Zyklus 60s an 150s aus
Simulation Ermittlung der solaren Deckungsrate für 5 Standorte bei einer Brenndauer von täglich 3,5 Stunden



Field Test

The publication is available in English and German.

Additional Info

The SOLAR 2007-1 Lantern (Solarprojekt Freilassing e.V.)has been upgraded with new LEDs of 80 lm/W.