Difference between revisions of "Photovoltaic (PV) Pumping"
***** (***** | *****) m |
***** (***** | *****) m |
||
Line 4: | Line 4: | ||
= Drinking Water Supply = | = Drinking Water Supply = | ||
<div>For sites up to about 2,000 inhabitants and pumping heads up to about 60 meters PV pumping systems are often more cost-effective than diesel pumps, or at least competitive. For larger systems, a combination of PV and diesel pumps has proven worthwhile (hybrid systems).</div><div>A big disadvantage are still the high investment costs for a PV pumping system which can be up to 2-3 times the investment for a comparable diesel pump in a village with 1,000-2,000 inhabitants. However, the overall costs (investment + operation) for small PV pumping systems (1 kWp) are well below of comparable diesel pumps. For medium size systems (2 kWp), comparison is still in favour of PV pumps. For systems of 4 kWp and larger, a break even situation arises which requires proper cost comparison depending on the local conditions.</div><div>There is broad application for medium-sized standard systems of 2kWp and a pumping capacity of 1,000 m<sup>4</sup>/day (m<sup>4</sup>/day = flow rate (m³) x pumping head (m) per day, equals e.g. about 35 m³/day x 30 m head) on sunny days. This amount of water is sufficient to supply about 1,400 people with 25 liters/person/day. A study from 2008 revealed for Senegal that solar pumping systems are more cost-effective than diesel pumps up to a pumping capacity of 3,150 m<sup>4</sup>/day. This equals a daily total amount of water of 45m³ with a pumping head of 70 meters supplying 2,000 people.<br/></div><div><br/></div> | <div>For sites up to about 2,000 inhabitants and pumping heads up to about 60 meters PV pumping systems are often more cost-effective than diesel pumps, or at least competitive. For larger systems, a combination of PV and diesel pumps has proven worthwhile (hybrid systems).</div><div>A big disadvantage are still the high investment costs for a PV pumping system which can be up to 2-3 times the investment for a comparable diesel pump in a village with 1,000-2,000 inhabitants. However, the overall costs (investment + operation) for small PV pumping systems (1 kWp) are well below of comparable diesel pumps. For medium size systems (2 kWp), comparison is still in favour of PV pumps. For systems of 4 kWp and larger, a break even situation arises which requires proper cost comparison depending on the local conditions.</div><div>There is broad application for medium-sized standard systems of 2kWp and a pumping capacity of 1,000 m<sup>4</sup>/day (m<sup>4</sup>/day = flow rate (m³) x pumping head (m) per day, equals e.g. about 35 m³/day x 30 m head) on sunny days. This amount of water is sufficient to supply about 1,400 people with 25 liters/person/day. A study from 2008 revealed for Senegal that solar pumping systems are more cost-effective than diesel pumps up to a pumping capacity of 3,150 m<sup>4</sup>/day. This equals a daily total amount of water of 45m³ with a pumping head of 70 meters supplying 2,000 people.<br/></div><div><br/></div> | ||
− | {| | + | {| style="width: 100%" cellpadding="0" cellspacing="0" border="1" |
|- | |- | ||
| width="158" | <div>'''PVP -Power'''</div> | | width="158" | <div>'''PVP -Power'''</div> | ||
Line 19: | Line 19: | ||
| width="139" | <div align="center">10</div><div align="center">30</div><div align="center">50</div> | | width="139" | <div align="center">10</div><div align="center">30</div><div align="center">50</div> | ||
| width="158" | <div align="center">100</div><div align="center">35</div><div align="center">20</div> | | width="158" | <div align="center">100</div><div align="center">35</div><div align="center">20</div> | ||
− | | valign="top" width="158" | <div align="center">4000</div><div align="center">1400</div><div align="center">800</div> | + | | valign="top" width="158" | <div align="center">4000</div><div align="center">1400</div><div align="center">800<br/></div> |
|- | |- | ||
| width="158" | <div>'''4 kWp''' (equals about 2000 m<sup>4</sup>/day)</div> | | width="158" | <div>'''4 kWp''' (equals about 2000 m<sup>4</sup>/day)</div> | ||
Line 29: | Line 29: | ||
− | {| | + | {| style="width: 100%" cellpadding="0" cellspacing="0" border="1" |
|- | |- | ||
| width="284" | <div>'''Average Investment [Euro]'''</div> | | width="284" | <div>'''Average Investment [Euro]'''</div> | ||
Line 37: | Line 37: | ||
|- | |- | ||
| width="284" | <div>'''Pumping System '''(PV-Generator, Inverter, Pump)</div> | | width="284" | <div>'''Pumping System '''(PV-Generator, Inverter, Pump)</div> | ||
− | | width="94" | <div align="center">8000</div> | + | | width="94" | <div align="center">8000<br/></div> |
| width="95" | <div align="center">15000</div> | | width="95" | <div align="center">15000</div> | ||
| width="85" | <div align="center">25000</div> | | width="85" | <div align="center">25000</div> | ||
Line 65: | Line 65: | ||
= Project Experiences<br/> = | = Project Experiences<br/> = | ||
− | Gesellschaft für Internationale Zusammenarbeit ([http://www.giz.de/en/ GIZ]) has experience of PVP irrigation in projects in Chile (smallholder farmers), Ethiopia (tree nursery Forestry Dep.) and Bangladesh (irrigation of paddy fields). | + | '''Gesellschaft für Internationale Zusammenarbeit ([http://www.giz.de/en/ GIZ])''' has experience of PVP irrigation in projects in Chile (smallholder farmers), Ethiopia (tree nursery Forestry Dep.) and Bangladesh (irrigation of paddy fields). |
− | Experience in Bangladesh has shown that PV panels can have significant spatial requirements depending on the energy needed. This leads to disadvantages for farmers. [http://www.kfw.de/kfw/en/index.jsp KfW ](German Development Bank) has supported the installation and dissemination of PVP pumps for irrigation in several countries in sub-Saharan Africa (Eritrea, Guinea, Mali, Namibia, Burkina Faso). At experimental level there are already technical solutions available for the application of PVP in stand-alone systems to irrigate an area of 30-40 hectares by using variable frequency drives (VFD) for any AC-motor. | + | Experience in Bangladesh has shown that PV panels can have significant spatial requirements depending on the energy needed. This leads to disadvantages for farmers. [http://www.kfw.de/kfw/en/index.jsp KfW ](German Development Bank) has supported the installation and dissemination of PVP pumps for irrigation in several countries in sub-Saharan Africa (Eritrea, Guinea, Mali, Namibia, Burkina Faso). At experimental level there are already technical solutions available for the application of PVP in stand-alone systems to irrigate an area of 30-40 hectares by using '''variable frequency drives (VFD)''' for any AC-motor. |
− | |||
− | |||
+ | = Further Information<br/> = | ||
− | + | *[https://energypedia.info/Photovoltaic%20%28PV%29%20Pumping%20in%20India Photovoltaic (PV) Pumping in India] | |
− | + | *[[Design_of_Photovoltaic_(PV)_Pumping|Design of Photovoltaic (PV) Pumping]] | |
*GIZ INTERNAL: [https://dms.gtz.de/livelink-ger/livelink.exe?func=ll&objId=57642651&objAction=browse DMS folder ]containing additional documents on PV pumping (documents also available upon request from [mailto:hera@gtz.de GTZ-HERA]) | *GIZ INTERNAL: [https://dms.gtz.de/livelink-ger/livelink.exe?func=ll&objId=57642651&objAction=browse DMS folder ]containing additional documents on PV pumping (documents also available upon request from [mailto:hera@gtz.de GTZ-HERA]) | ||
*[http://net.grundfos.com/doc/webnet/renewables/solar.html Product overview ] and [http://net.grundfos.com/doc/webnet/renewables/cases.html cases] of market leader Grundfos | *[http://net.grundfos.com/doc/webnet/renewables/solar.html Product overview ] and [http://net.grundfos.com/doc/webnet/renewables/cases.html cases] of market leader Grundfos | ||
*[[Decentralized Drinking Water Supply|Drinking water supply]] | *[[Decentralized Drinking Water Supply|Drinking water supply]] | ||
+ | |||
+ | |||
+ | |||
+ | = References<br/> = | ||
+ | |||
+ | <references /> | ||
[[Category:Pumping]] | [[Category:Pumping]] | ||
[[Category:Solar]] | [[Category:Solar]] | ||
[[Category:Water_Supply]] | [[Category:Water_Supply]] |
Revision as of 09:22, 11 October 2012
Introduction
Drinking Water Supply
PVP -Power
|
Head [m]
|
Flow Rate [m³]
|
People Supplied (Consuming 25 l/c*d)
|
1 kWp (equals about 500 m4/day)
|
10 30 50
|
50 15 10
|
2000 600 400
|
2 kWp (equals about 1000 m4/day)
|
10 30 50
|
100 35 20
|
4000 1400 800
|
4 kWp (equals about 2000 m4/day)
|
10 30 50
|
200 65 40
|
8000 2600 1600
|
Average Investment [Euro]
|
1 kWp
|
2 kWp
|
4 kWp
|
Pumping System (PV-Generator, Inverter, Pump)
|
8000
|
15000
|
25000
|
Ready-to-operate PV Pumping System (Pumping system, logistics, set-up, reservoir, construction, water distribution)
|
16000
|
25000
|
41000
|
Irrigation
- In order to reduce the energy requirements of PVP irrigation systems water-conserving and energy-saving micro-irrigation techniques have to be applied.
- The plot size for PVP irrigation should be below 4 hectares.
- High rates of system utilisation are necessary to achieve economic viability of PVP irrigation systems.
- Therefore PVP systems are limited to irrigate permanent crops and continuous crop rotation in arid climates.
- High value-added cash crops like fruits, vegetables and spices should be given preference to recoup the high initial investment.
- Low-interest loans should be available for the same reason.
- PVP irrigation systems require a careful planning of the crop schedule and are more demanding of user skills.
Project Experiences
Gesellschaft für Internationale Zusammenarbeit (GIZ) has experience of PVP irrigation in projects in Chile (smallholder farmers), Ethiopia (tree nursery Forestry Dep.) and Bangladesh (irrigation of paddy fields).
Experience in Bangladesh has shown that PV panels can have significant spatial requirements depending on the energy needed. This leads to disadvantages for farmers. KfW (German Development Bank) has supported the installation and dissemination of PVP pumps for irrigation in several countries in sub-Saharan Africa (Eritrea, Guinea, Mali, Namibia, Burkina Faso). At experimental level there are already technical solutions available for the application of PVP in stand-alone systems to irrigate an area of 30-40 hectares by using variable frequency drives (VFD) for any AC-motor.
Further Information
- GIZ INTERNAL: DMS folder containing additional documents on PV pumping (documents also available upon request from GTZ-HERA)
- Product overview and cases of market leader Grundfos
- Drinking water supply