Best Practice: Cogeneration in Palm Oil Industry in Honduras

From energypedia
Revision as of 14:02, 23 June 2016 by ***** (***** | *****) (Created page with " <font lang="ja" face="bundesserif-regular" size="2"><font lang="ja" face="bundesserif-regular" size="2"</font></font>In order to raise awareness of the promising [[Cogenerati...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

<font lang="ja" face="bundesserif-regular" size="2"In order to raise awareness of the promising cogeneration technology - also in the context of developing and emerging economies - this "best practice" example shall illustrate possible fields of application. Concretely, this article will give you a brief overview of a project in El Negrito, Honduras, where organic waste gas-fired cogeneration has been successfully integrated in a palm oil factory.

Technical detail of the implementation

HonduPalma, one of the leading palm oil manufacturers in Central America ordered acomplete and highly efficient 1.2 MW 2GR biogas CHP cogeneration system. The fullyintegrated prime mover of the CHP System is a 2GR avusR 1200 with an MWMR coreengine and a capacity of 1,200 kWelor 9,960 MWh p.a. electrical power and 1,225 kWthof thermal power. In addition to the CHP cogeneration unit, 2G CENERGY also suppliedthe complete gas treatment, including cooler, dryer / dehumidification, and the H2Sremoval system.

Benefits

The biogas energy conversion plant provides electricity to HonduPalma’s factory and oilprocessing facility, as well as feeding surplus electricity into the utility grid. The thermalenergy is fully utilized in the palm oil processing facility.

Key Facts


Gas engine capacity

1,200 kWel

1,225 kWth 

Fuel
Biogas

Fuel source

Anaerobic digestion of organic waste
Configuration
container module
Heat utilization
Thermal distribution to oil processing facility
electricity generation p.a.
9,960 MWh/a
Heat generation p.a.
10,167 MW/a
Full load hours p.a.
8,300

Further Information